Laserfiche WebLink
STI Aboveground SEGoal <br /> nk Report Formal External Inspection COVEY AUTO EXPRESS,Stockton,CA <br /> Storage Tank Repo /2014 Tank No.5_200 GA Poly Vertical Cylindrical-Used Antifreeze <br /> InspectioMethods Employed Results <br /> 7,1 GENERAL <br /> 7.1.1 Formal External Certification Name and Number Daniel K. Barber <br /> Inspection is to be <br /> STI Certified <br /> certified Inspector performed Level 11 AST SAC 18709 <br /> 7.1.2 Applicable Check List Horizontal and Vertical Cylindrical Single Wall,Steel See Below for each AST <br /> Horizontal Rectangular Double Wall,Steel Photos attached <br /> Containment&Accessories-Visual,Ultrasonic Thickness <br /> Testing ft n-r' History. <br /> 7.1.3 Review History Interview long time employees Inspection and Drain Release Discuss with Mike Covey,Jr. <br /> Records. Truck Shop Management <br /> 7.1.4A Record AST Locate Plate,-Manufacturer,Date,Design Standard.Serial 7200'GA, Poly Vertical <br /> Nameplate Data No. Cylindrical 2.9'diameterx <br /> Capacity,shell thickness,diameter,length 4.5'tall <br /> 7.1.46 Record Inspection Apply Visual,Ultrasonic&other methods,Photograph and OK <br /> Findings&Problems Record findings. <br /> 7.1.5 inspect Fabrication Compare to UL,SWI,STI or other industry standards, OK <br /> vs.Industry Standards modifications to original AST. <br /> 7.1.6 Verify Foundation Visual examination for concrete cracking,spalling,washout, Sound PCC Shop <br /> Integrity voids,settling,slope from AST,standing water,soil contact, Containment floor <br /> seepage. <br /> 7,1,7 Visually Inspect Cracking or spalling,corrosion,anchorage,weld failure or OK <br /> Supports stress,saddle pads. <br /> Visually Inspect Visual examination for cracking,spalling,welds, Shop Floor Barrier,no <br /> Secondary containment,penetrations,other containers,basis of secondary container <br /> Containment,Spill volume calculations,drain valves dosed&secured,debris <br /> Control&CRDM free,& personnel access. <br /> Containment ID <br /> 7,1,9A Inspect Ancillary Inspect operability of pumps,valves and piping for stress, N/A <br /> Equipment-Pumps leakage,fusible links,for corrosion,wiring conduit integrity. <br /> Fill point containment,Camlock connectors <br /> 7,1,98 Inspect Ancillary Inspect operability of emergency relief&normal venting, None <br /> Equipment-Vents continuity of vapor containment <br /> 7.1.9C Inspection Ports Interstitial n/a Verify no leakage Into secondary interstitial N/A <br /> 7.1.9D Inspect Ancillary No level gauge Translucent opaque AST, <br /> Equipment-Liquid content level readily <br /> Level visible <br /> 7.1.9E Inspect Alarms Overfill Alarm Only none on secondary interstitial volume No alarm <br /> 7.1.10 Inspect Bonding and Refer to NFPA 780 Standards for Installation of Lightning N/A <br /> Grounding,if present Protection Systems. <br /> 7.1.11 Inspect Stairways, Inspect for broken welds,bent members,corrosion,debris N/A <br /> Handrails&Platforms free. <br /> 7.1.12 Inspect Coatings& Exterior of shell,heads,supports and interference with Trinity Antifreeze <br /> Labels equipment,Signage. <br />