Laserfiche WebLink
Alternate construction for new underground storage tanks containing motor vehicles fuel (Section 26331. <br /> _ (1) Monitoring and response plan (Section 26341. <br /> (2) Underground storage tank composed of.... <br /> (a) Fiberglass reinforced plastic. <br /> (b) CathodicaLly protected steel. <br /> _X (c) Steel clad with fiberglass reinforced plastic. <br /> (d) Other material that complies with section 2631 and 2632. <br /> (3) Floor of leak interception and detection system constructed on a firm base and sloped to a <br /> collection sump (use of membrane liners comply with section 2631 (d) (6) requirements.) <br /> (4) Access casings installed in the collection sumo of the secondary containment system with <br /> backfill in the interstitial space. The access casing shall meet all of the following: <br /> Designed and installed to allow the liquid to flow into the casing. <br /> Sized to allow removal of collected liquid and able to withstand all anticipated applied <br /> stresses. <br /> _ Constructed of material that will not be structurally weakened. <br /> Screened along entire vertical zone of permeable material. <br /> Capable of preventing leakage of any hazardous substance from the casing. <br /> Extend to the ground surface and covered with a locked waterproof cap. <br /> Capable of meeting S.J. Co. PHS-EHD ueLL Standards. <br /> Leak interception and detection system shall prevent the leaked hazardous substance rrom <br /> entering ground water. <br /> 14. INTERSTITIAL SPACE MONITORING <br /> A. Visual monitoring (Section 2632 (c) (1)] <br /> (a) Exterior surface and floor beneath tank monitored by direct viewing <br /> (b) Daily visual inspections <br /> (c) Liquid Level in tank to be recorded at time of inspection <br /> (d) If liquid observed around or beneath primary tank, owner will determine if an unauthorized release <br /> has occurred. <br /> B. Mechanical or electronic monitoring (Section 2632 (c) (2)] <br /> X (a) Continuous monitoring system connected to an audible and visual alarm system. <br /> Monitoring equipment to be installed <br /> _]t <br /> Manufacturer: <br /> X Model Number <br /> _ Sensor Type: Vapor _X Liquid Both. SI��rL �`���/✓ <br /> _ Sensor/Panel specifications. <br /> _ Locarion(s) for sensors: �rsl/Y ��lrYV <br /> Tank: ANVLAR—SUMPSPiping: '�y/ ✓ � �G/ J <br /> Dispenser LIQUID <br /> — _. /I u d <br /> C. Monitoring and response plan submitted (Section 2632 (d) (1) b (2)]. <br /> 5• Any special accessories, fittings, coatings, or linings not inherent within the initial design of the 10 tank or <br /> double-wall UST. (Section 2631 (b)] <br /> A. Approved by a nationally recognized independent testing organization. <br /> B. Demonstration of integrity with the primary and/or secondary containment. <br /> - <br /> 6 <br />