Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for NATIONAL PETROLEUM MANTECA as of December 16 , <br /> 2020 . <br /> Open violations from September 21 , 2020 inspection <br /> xThis violation was corrected ❑ This violation will be corrected by ( date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : afforda test is doing D . O . inspection every 30 days <br /> Violation #210 - No employee present that were trained in the operation and maintenance of the UST system <br /> by a DO . <br /> OBSERVATION : The designated operator employee training for Pavitor Singh was not performed . <br /> REGULATION GUIDANCE : The designated operator shall train facility employees in the proper operation and <br /> maintenance of the UST system at least once every 12 months. The training shall be conducted before the <br /> individual performs the duties of a facility employees . The training shall include , but is not limited to: <br /> 1 . Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2 . Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br /> Initial training shall also include a site-specific practical demonstration that provides both sharing information and <br /> evaluating knowledge for responding to emergencies , leak detection , monitoring alarms , spills and overfills . At least <br /> one of the facility employees present during operating hours shall have current training . <br /> CORRECTIVE ACTION : Ensure that employees have been trained by the designated operator, maintain the list on <br /> site , and submit a copy of the training records to the EHD . <br /> XThis violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : trained all current employees and we will keep <br /> training new employees before they start the job . <br /> Violation #304 - Failure to construct, operate , and maintain primary containment as product-tight. <br /> OBSERVATION : Large amount of oily liquid was observed in UDC 5/6 , indicating a leak in the primary containment. <br /> REGULATION GUIDANCE : All primary containment for the UST system must be product tight. <br /> CORRECTIVE ACTION : Immediately have a properly licensed , trained , and certified contractor repair or replace the <br /> failed component(s) , under permit and inspection of the EHD if necessary. <br /> Page 4 of 5 <br />