Laserfiche WebLink
SWRCB , January 2002 Page of <br /> 6. SECONDARY PIPE TESTING <br /> Test Method Developed By : X Piping Manufacturer 11 Industry Standard ❑ Professional Engineer <br /> r <br /> ❑ Other (Spec) <br /> Test Method Used : X Pressure ❑ Vacuum ❑ Hydrostatic <br /> ❑ Other (Specify) <br /> Test Equipment Used : Pressure Gauges in Psi/Nitrogen Equipment Resolution : 1 / 1045 Psi <br /> Piping Run #5 Piping Run #6 Piping Run # Piping Run # <br /> Piping Material : Fiberglass Fiberglass <br /> Piping Manufacturer : Ameron Ameron <br /> Piping Diameter: 2" 2" <br /> Length of Piping Run : Approx. 30 ' Approx. 45 ' <br /> Product Stored : Diesel Race 100 <br /> Method and location of Test boot at STP Test boot at STP <br /> i in -run isolation : Piping Sump #5 Piping Sump #6 <br /> Wait time between applying 5 Minutes 5 Minutes <br /> pressure and starting test : <br /> Test Start Time : 10 : 20 10 : 25 <br /> Initial Reading (RI) : 5 Psi 5 Psi <br /> Test End Time : 11 : 20 11 : 25 <br /> Final Reading (RF) : 5 Psi 5 Psi <br /> Test Duration : 1 Hour 1 Hour <br /> Change in Reading (RF-RI) : 0 Psi 0 Psi <br /> Pass/Fail Threshold or No Loss in Psi No Loss in Psi <br /> Criteria : <br /> Test Result: Pass Pass <br /> Comments — (inchide information on repairs made prior to testing, and recommended follolsv-up for failed tests) <br />