My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2021 8:05:52 AM
Creation date
1/17/2020 2:36:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231426
PE
2361
FACILITY_ID
FA0004625
FACILITY_NAME
NATIONAL PETROLEUM MANTECA
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
01
SITE_LOCATION
2072 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB , January 2002 Page of <br /> 7. PIPING SUMP TESTING <br /> Test Method Developed By : ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br /> ❑ Other (Spec) <br /> Test Method Used : ❑ Pressure ❑ Vacuum X Hydrostatic <br /> ❑ Other (Spec) <br /> Test Equipment Used : Caldwell Level Change Indicator Equipment Resolution : . 002 <br /> Sump # 1-87-M Sump # 2-87-S Sump # 3 -91 Sump # 4-Race 110 <br /> Sump Diameter: 42" 42" 42" 42" <br /> Sump Depth : 40" 40" 401/2 31 " <br /> Sump Material . Fiberglass Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of Product 5 " Vapor/Vent 15 " Vent 15 " Vent/Vapor 20" <br /> Highest Piping Penetration : Siphon 13 " Siphon 12" Product 5 " Product 13 " <br /> Height from Tank Top to Lowest 10" 10" 12" 4" <br /> Electrical Penetration : <br /> Condition of sump prior to testing : Dry Dry Dry Dry <br /> Portion of Sump Tested ' Water Level 17" Water Level 19" Water Level 20" Water Level 24" <br /> Does turbine shut down when <br /> sump sensor detects liquid (both Yes Yes Yes Yes <br /> product and water)?* <br /> Turbine shutdown response time Not Alarmed Not Alarmed Not Alarmed Not Alarmed <br /> Is system programmed for fail-safe Yes Yes Yes Yes <br /> shutdown? ` <br /> Was fail-safe verified to be No No No No <br /> operational? * <br /> Wait time between applying water 5 Minutes 5 Minutes 5 Minutes 5 Minutes <br /> and starting test: <br /> Test Start Time : 11 : 37 11 :42 12 : 22 10 : 47 <br /> Initial Reading (RI) : . 001 . 001 . 001 . 001 <br /> Test End Time : 12 : 07 12 : 12 12 : 52 11 : 17 <br /> Final Reading (RF) : . 001 . 001 . 001 .001 <br /> Test Duration : 30 Minutes 30 Minutes 30 Minutes 30 Minutes <br /> Change in Reading (RF-Ri) : 0 0 0 0 <br /> Pass/Fail Threshold or Criteria: . 005/30 Minutes . 005/30 Minutes . 005/30 Minutes . 005/30 Minutes <br /> Test Result: Pass Pass Pass Pass <br /> Was sensor removed for testing? Yes Yes Yes Yes <br /> Was sensor properly replaced and Yes Yes Yes Yes <br /> verified functional after testing? <br /> Comments — (include information on repairs made prior to testing, and recommended follow-up for•failed tests) <br /> 1 If the entire depth of the sump is not tested, specify how much was tested . If the answer to any of the questions indicated with an <br /> asterisk ( *) is "NO" or "NA" , the entire sump must be tested . ( See SWRCB L& 160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.