My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_FOURTH QUARTER_ANNUAL 2008 GROUNDWATER MONITORING REPORT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
22888
>
2900 - Site Mitigation Program
>
PR0519076
>
ARCHIVED REPORTS_FOURTH QUARTER_ANNUAL 2008 GROUNDWATER MONITORING REPORT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2020 5:27:08 PM
Creation date
2/5/2020 3:36:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
FOURTH QUARTER_ANNUAL 2008 GROUNDWATER MONITORING REPORT
RECORD_ID
PR0519076
PE
2950
FACILITY_ID
FA0014276
FACILITY_NAME
CHEVRON BULK TERMINAL 100-1621 UST
STREET_NUMBER
22888
Direction
S
STREET_NAME
KASSON
STREET_TYPE
RD
City
BANTA
Zip
95304
APN
23906019
CURRENT_STATUS
02
SITE_LOCATION
22888 S KASSON RD
P_LOCATION
99
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> ARCADIS Brian Taylor, P.G. <br /> February 2,2009 <br /> 1 <br /> Passive versus Standard Sampling Technique Evaluation <br /> ARCADIS proposes to perform an evaluation of monitoring and sampling techniques <br /> (passive versus standard purge and sampling).The purpose of the evaluation is to <br /> investigate the feasibility of passive sampling techniques to collect groundwater <br /> samples during the monitoring and sampling program for the site.To facilitate the <br /> study ARCADIS will perform comparison sampling at the following monitoring wells: <br /> MW-5A, MW-12B, MW-28A, MW-29A, MW-31 A, MW-32A, MW-39UA, MW-65B, <br /> MW-67UA, and MW-69UA. ARCADIS will sample the monitoring wells using three <br /> passive sampling methods to compare data with the standard 3 well volume purge <br /> and sampling technique used currently during site-wide during quarterly monitoring <br /> and sampling.The three passive sampling techniques include: <br /> Grab Groundwater <br /> Snap Sampler' <br /> HydraSleeve® <br /> These no-purge groundwater sampling methods are discussed below. <br /> Snap Sampler T1" <br /> The Snap SamplerTm employs standard-sized 40-milliliter(mL)glass VOA vials with <br /> double-end openings. Specialty Teflon®end caps seal water within the Snap <br /> SamplerTM vial with an internal closure spring made of perfluoroalkoxy-(PFA <br /> Teflon®)coated stainless steel.To deploy the sampling device,the vial is placed <br /> inside the Snap SamplerT", and the end closure caps are attached to the sampler's <br /> trigger mechanism in an open position.The trigger cable is secured at the top of the <br /> well using a docking station.As many as four vials can be attached in series with one <br /> trigger cable.After a recommended minimum 72-hour equilibration period,the trigger <br /> is activated, "snapping"the sample vial(s)closed.The vial(s) are retrieved and <br /> remain closed prior to sample analysis. <br /> 1 <br /> Sampling Event <br /> Using the Snap SamplerT61 technology, ARCADIS will set four 40-mL glass VOA vials <br /> in series on a trigger cable(rig)at the mid-point of the well screen interval.The well <br /> and rig will be allowed the manufacturer's recommended 72-hour equilibration period <br /> I <br /> Page: <br /> 2/5 <br /> IWgOeubfiwmnl5xturcnbCR'fMAL1EMLM1W1611W OdwWIMWUMPYrM>P"V��htln'AMhipMmmhEon�m"�T`�10350.6x <br /> 1 <br />