Laserfiche WebLink
A 3000 gallon water truck will be used for dust control and shall <br /> remain on site at all times until completion of material to be removed. <br /> A 5 cubic yard wheel loader will be used to load dump trucks at site. <br /> During and at the completion of material to be replaced over excavated <br /> a laser land leveling tractor with scraper will be used to level area that <br /> was disturbed. <br /> d) TOPSOIL/OVERBURDEN <br /> The topsoil to be replaced over the excavated area from the field <br /> (48.9 acres) at 2.5 feet in depth consists of 176,500 cubic yards. <br /> The topsoil over the excavated area will be not be used as this <br /> area is too sandy from many years of discing and deep ripping <br /> which brought up and mixed into the existing topsoil making it <br /> a poorer quality of soil. No outside fill material will be used at <br /> the project site, no recoiling is needed as the good quality topsoil <br /> needs no special additions as shown on soils report. <br /> There is no overburden on this site. <br /> e) MINE WASTE <br /> There will be no mine waste discharge associated with the excavation <br /> permit. All excavated materials will either be processed or used for <br /> reclamation. <br /> f) SIZE <br /> Total acres to be permitted is fifty seven (57.7) <br /> Total acres to be disturbed is fifty seven (57.7) <br /> Total acres to be reclaimed is fifty seven (57.7) <br /> 4 <br />