PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
476
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: Sump Manufacturer v Industry Standard Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum D Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used:Calibrated gauges Equipment Resolution:0.00" <br /> Sump#87 Sump#91 Sump#Diesel Sump# <br /> Sump Diameter: 39.00" 39.00" 39.00" <br /> Sump Depth: 71.00" 73.00" 72.00" <br /> Sump Material: Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of 26.00" 31.00" 33.00" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 42.00" 38.00" 41.00" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Clean dry Clean dry Clean dry <br /> Portion of Sump Tested .00"above highest pipe U 4.00"above highest pip 4.00"above highest pip <br /> Does turbine shut down when 7 Yes ❑No ❑NA <br /> sump sensor detects liquid(both Z Yes ❑No DNA Z Yes ❑No ' NA Yes No NA <br /> product and water)?* <br /> Turbine shutdown response time Immediately Immediately Immediately Immediate) <br /> Is system programmed for fail-safe v Yes D No D NA Z Yes ❑No NA Z Yes ❑No [INA Yes .._No NA <br /> shutdown? <br /> Was fail-safe verified to be , Yes ❑No ❑NA <br /> Yes ❑No 1 NA W Yes ❑No ElNA ❑Yes ❑No NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5 min 5 min <br /> test: <br /> Test Start Time: <br /> InitialdTime:g(RI): <br /> Test End Time. Please See ancon results <br /> Final Reading(RF): <br /> Test Duration: 15 min 15 min 15 min <br /> Change in Reading(RF-Rl): <br /> Pass/Fail Threshold or Criteria: 0.002" 0.002" 0.002" <br /> Test Result: Pass ❑Fail Li Pass ❑Fail Pass Fail Pass Fail <br /> Was sensor removed for testing? ' Yes No -]NA ❑Yes Li No - NA vi Yes No NA Yes No _-NA <br /> Was sensor properly replaced and Yes No ❑NA 121 Yes D No ❑NA ❑Yes D No -NA ❑Yes []No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />