MONITORING AND REATING PROGRAM NO. • - 2-
<br /> Lincoln
<br /> 2-Lincoln Center, Stockton
<br /> San Joaquin County
<br /> implement any changes to this MRP unless and until a revised MRP is issued by the Executive
<br /> Officer.
<br /> Prior to construction of any new groundwater monitoring or extraction wells, the Discharger shall
<br /> submit plans and specifications to the Board for review and approval. Once installed, all new
<br /> wells shall be added to the monitoring program and shall be sampled and analyzed according to
<br /> the schedule below.
<br /> GROUNDWATER MONITORING
<br /> As shown on Figure 1, there are 31 A-zone monitoring wells, 16 B-zone monitoring wells, three
<br /> C-zone monitoring wells, one water supply well, 22 piezometers, six monitoring wells associated T
<br /> with the former Chevron station(three are sampled by Lincoln Trust), and 12 monitoring wells K
<br /> associated with a former Exxon station(not sampled by Lincoln Trust). Monitoring wells
<br /> MW-011A and MW-102A are not sampled due to their proximity to monitoring well MW-101A.
<br /> The groundwater monitoring program for 52 of the monitoring wells and any wells installed
<br /> subsequent to the issuance of this MRP, shall follow the schedule below. The volume of
<br /> extracted groundwater also shall be provided in bi-annual monitoring reports. Reporting
<br /> requirements in National Pollutant Discharge Elimination System Permit No. CA0084255 and
<br /> Waste Discharge Requirements Order No. 98-062 shall be submitted under separate cover as A
<br /> specified. Sample collection and analysis shall follow standard EPA protocol. A
<br /> SAMPLING FREQUENCY[
<br /> ti Tri-annual i-annua12 Annua13
<br /> Wells MW-003A,MW-004A,MW-006A, j!02A,MW-005A, MW-001A,MW-008A,MW-100A,
<br /> MW-007A,MW-010A,MW-012A, 104A,MW-009A, MW-103A,MW-105A,MW-106A,
<br /> MW-101A,MW-108A,MW-109A, 112A,MW-114A, MW-107A,MW-110A,MW-111A,
<br /> MW-113A,MW-116A, CHMW-002A, MW-115A, MW-208B, MW-117A,MW-118A,MW-020B,'
<br /> CHMW-003A,CHMW-005A, MW-20913,MW-21013, MW-200B,MW-201B,MW-203B-3,
<br /> MW-20313-1,MW-203B-2,MW-20513, MW-211B,MW-21213, MW-20413,MW-206B,MW-21313,
<br /> MW-207B COs#11 MW-030C,MW-300C,MW-301C
<br /> All wells will be monitored tri-annually for water levels.
<br /> 2 Wells will be sampled bi-annually during the first and third tri-annual events.
<br /> Wells will be sampled annually during the second tri-annual event.
<br /> EPA Analytical Maximum Detection
<br /> Constituents Method t
<br /> Limit (ug/1)
<br /> Depth to Groundwater ---
<br /> Volatile Organic 8010 or 8260B 0.5
<br /> Compounds
<br /> 1 For nondetectable results.