Laserfiche WebLink
..i <br /> Ford Construction <br /> VFF No. 1 In'ection Well <br /> Page 2 <br /> Abandonment Program (assuming caaing integrity is not OK) <br /> 4. Using Halliburton, equalize 240 sacks Class G cement premixed with 0.1% <br /> retarder on top of cement plug around 15901 . Notify EPA to witness. <br /> After 12+ hours tag top of cement plug which must be around 300' . EPA <br /> to witness. <br /> 5. Cut casing 5' below ground. Using rig pumps equalize 60 sacks Class <br /> G cement premixed 2% CaC12 at 300' . The top of cement should be at <br /> surface. EPA to witness. Weld steel plate on stub. <br /> April 1, 2006 <br />