Laserfiche WebLink
3.0 PRO CED URE FOR SAMPLING SOIL AND GR O UND WA TER USING <br /> HOLLOW-STEM AUGERS <br /> 3.1 LIST OF NECESSARY EQUIPMENT <br /> Typical equipment for sampling soil and groundwater includes: <br /> • Auger rig with appropriate equipment for sampling. <br /> • CME or equivalent continuous soil sampler (2 1/2 inch x 5-foot <br /> split spoon sample tube). <br /> • California modified samplers (2-1/2 inch x 18-inch split spoon). <br /> • Stainless steel or brass tubes. <br /> • Teflon film. <br /> • Plastic caps. <br /> • Self-adhesive labels. <br /> • Ice chests/coolers. <br /> • Ice or frozen ice packs. <br /> • Field notebook and location map. <br /> • Personal protective equipment, including nitrile or powderless <br /> surgical gloves, hard hat, steel-toed boots, and respirator. <br /> Photo Ionization Detector (PID) or Flame Ionization Detector <br /> (FID). <br /> • Field notebook and/or data collection forms. <br /> Typical equipment for decontamination: <br /> • High-pressure steam-cleaner (may be provided by drilling contrac- <br /> tor). <br /> • Water sprayer. <br /> • Long-handled bristle brushes. <br /> • Wash/rinse tubs. <br /> • Alconox detergent (or equivalent). <br /> • Organic-free deionized water. <br /> 3-1 <br />