My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2023 10:33:18 AM
Creation date
5/5/2020 3:36:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page of <br /> 8. FILL RISER CONTAINMENT SUMP TESTING a <br /> Facility is clot Equipped With Fill Riser Containment Sumps <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Speer) <br /> "fest Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .002 <br /> Fill Sump # 1 Fill Sump #2 _--Fill Sump#3 Fill Sump It <br /> Sump Diameter: 48" 48" 48" s <br /> Sump Depth: 78" — 78" -- -- 780" - -- <br /> Height fi•on-i Tank Top to Top of No Piping No Piping No'Piping <br /> Highest Piping Penetration: Penetrations Penetrations Penetrations _ <br /> Height from Tank Top to Lowest 39" 41" 35" <br /> Electrical Penetration: <br /> Condition of sump prior to Dry Dry Dry <br /> testing: <br /> Portion of Sump Tested Water Level 41" Water Level 43" Water Level 38" _ <br /> Sump Material: Fiberglass Fiberglass Fibergla s <br /> Wait time between applying 5 Minutes 5 Minutes 5 Minutes <br /> water and starting test: _ <br /> Test Start Time: 7:25 8:15 _ 9:05_ <br /> Initial Reading(Rj): .001 .001 J001 <br /> Test End Time: 7:55 8:45 9:35 _ <br /> Final Reading(RF): .001 .001 .001 <br /> Test Duration: 30 Minutes 30 Minutes 30 Minutes <br /> Change in Reading(RF-Rj): 0 0 0 — <br /> Pass/Fail Threshold or Criteria: .005/30 Minutes .005/30 Minutes .005/39 Minutes _ <br /> Test Result: X Pass ❑Fail X Pass ❑Fail X Pasj ❑ Fail ❑ Pass ❑ Fail <br /> Is there a sensor in the sump? X Yes ❑No X Yes ❑No X Yes No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑No ENA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑lNo ❑NA ❑Yes ❑No E NA <br /> Was sensor properly replaced and X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑INo ❑NA ❑Yes ❑No 0 NA <br /> verified functional after testing? <br /> Comments — (include infavnation on repairs made prior to testing, and t-ecommendedfollow-up forfailed tests) _ <br />
The URL can be used to link to this page
Your browser does not support the video tag.