Laserfiche WebLink
KLEINFELDER <br /> During the purging of the wells, field parameters (pH, conductivity, and temperature) were <br /> monitored. Water samples were collected after field parameters had stabilized and <br /> approximately three well volumes of water was purged from the well. In addition to the <br /> routine samples collected from each well, a duplicate sample was collected from MW-1. <br /> The samples were stored in iced chests and transported under chain-of-custody procedures <br /> to ENSECO-California Analytical Laboratory in West Sacramento, California. A copy of <br /> the laboratory analytical report and chain-of-custody are contained in Appendix C. The <br /> monitoring well purge characteristics are presented in Table 2, Monitoring Well Purging <br /> and Sampling Data. <br /> All developing and sampling equipment were thoroughly washed in trisodium phosphate <br /> solution and rinsed in distilled water or steam cleaned prior to use in each monitoring well. <br /> I <br /> I <br /> i <br /> i <br /> i <br /> L <br /> 1S6-88-2362 6 <br />