• network), the plans for upgrade (with supporting data) will be discussed with the client and the <br /> SJVPCD Additional details on the system evaluation process are provided in Section VTI <br /> Operation, Monitoring, and Performance (OMP) Plan <br /> Recovered Water <br /> A licensed waste transporter will transport recovered fluids from the moisture separator (5-201)to <br /> a licensed recycling/disposal facility on an as-needed basis To keep operating costs low, these <br /> fluids will be disposed in conjunction with the development/purge water from the groundwater <br /> monitoring events <br /> H. CONTINGENCY PLAN <br /> During startup of the remedial system, monitoring will be performed daily for three (3) days and <br /> biweekly (every two weeks) thereafter, to confirm treatment effectiveness and maintain the proper <br /> operation of the system The system will be optimized during this monitoring period to ensure it is <br /> operating within design and effluent/emissions parameters If any portion of the system is found to <br /> be ineffective following optimization, the client will be promptly notified The system will be shut <br /> down if necessary Available field data and other factors will be examined and evaluated by the <br /> • engineer to consider modifications Any proposed modifications to the remediation system will be <br /> submitted to the client and SJV personnel for approval prior to implementation of any modifications <br /> I. IMPLEMENTATION SCHEDULE <br /> Implementation of the system will progress in three stages pre-installation, installation, and start-up <br /> activities Pre-installation will involve well installation and obtaining the appropriate construction <br /> permitting Installation will include equipment procurement, shipment, installation, piping, and <br /> electrical connections (with pre-startup testing) Startup will include actual system startup and <br /> equipment optimization for up to 5 days All aspects of the HASP will be followed during each <br /> stage of the installation Before system start-up, the a System Review Checklist(SRC) checklist will <br /> be completed and implemented A copy of the SRC will be included in the OMP manual <br /> The procurement of the equipment will be initiated upon State approval of this RAP and is expected <br /> to take 5 to 6 weeks The installation of the treatment system will commence within 3 to 4 weeks <br /> prior to the expected receipt of the equipment The time required for the construction portion of the <br /> system installation is estimated to be 3 to 4 weeks The total time required, from client approval to <br /> system start-up, is anticipated to take approximately 12 to 14 weeks <br /> V-S <br />