My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2142
>
2200 - Hazardous Waste Program
>
PR0536264
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 3:21:44 PM
Creation date
6/3/2020 9:22:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0536264
PE
2228
FACILITY_ID
FA0020842
FACILITY_NAME
Jazz Group Inc.
STREET_NUMBER
2142
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
24130058
CURRENT_STATUS
01
SITE_LOCATION
2142 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2228_PR0536264_2142 W YOSEMITE_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
450
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Seismic/Anchoring: <br /> Seismic/dynamic/hydrostatic load calculations are provided as Attachment 1. The UL <br /> licensed double wall AST, was tested in conformance with the Steel Tank Institute's 5th <br /> ed. protocol. <br /> Seismic/Anchoring Findings: The tank as designed, and operated, and the containment <br /> area ( secondary shell) are seismically sound. Safety factor against movement or seismic <br /> overturning exceeds 2.0 <br /> Initials: <br /> Leak Test: 191(g)(9)/192(k)(10) <br /> The secondary containment void was examined for leakage from the primary shell as <br /> well as the exterior of the tank. No leakage was apparent. <br /> Integrity Testing Findings: Based on the above noted integrity test and results obtained from <br /> that test, the tank has sufficient integrity for its intended use. <br /> Initials: <br /> Please reference attachment 1 for dimensions and photos of tank. <br /> Design of Containment Area 66264.193(e)(1)(D) and 66264.193(b)(1 & 3) <br /> The AST is a double walled steel tank was manufactured by Hoover Manufacturing in <br /> early 1990's. The manufacturing and servicing of this tank design was purchased by <br /> Containment Solutions in mid 1990's. Secondary containment is provided by the integral <br /> exterior 10 gage welded shell. Leak detection is provided by monthly visual observation <br /> of entirely visible exterior shell and secondary containment volume. <br /> Visual Inspection of Containment Area: 66264.193(e)(1)(C) <br /> The tank is located on a Portland cement pad with minimal contained drainage to a central <br /> readily visible curbed swale. All materials are compatible with the contained waste oil. AST's <br /> integral secondary containment is sufficient. Minor leakage from drummed hazardous waste i.e. <br /> drained oil filters and floor sweep would be captured. Merit of additional capacity from curbing <br /> versus increased risk of injury when handling stored drums must be considered. <br /> Imperial Truck Wash and Repair Waste Oil AST pg.3 of4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.