My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/5/2021 1:25:02 PM
Creation date
6/3/2020 9:45:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231129_3202 W HAMMER_2013-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
509
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> SWRCB,January 2002 Page 1 of 1 <br /> 8.FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps r <br /> Fill Riser Containment Sumps are Present,but were Not Tested <br /> Test Method Developed By: Sump Manufacturer Industry Standard Professional Engineer <br /> r.7 Other(Specify) <br /> Test Method Used By: Pressure Vacuum70, Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used:VPLT Equipment Resolution:0.00001 in. <br /> Fill,Ccntaat fvr Corrtatnent Fi1lCnntatnent fctr <br /> Trtk T1 RUI 1 <br /> P l Tank l 3 r'Di' <br /> Sump Diameter: 48.00 in. 48.00 in. 48.00 in. in. <br /> Sump Depth: 66.00 in. 67.00 in. 65.00 in. in. <br /> Height from Tank Top to Top of 53.00 56.00 54.00 <br /> Hi hest Pi2ing Penetration: <br /> Height from Tank Top to Lowest 4500 48.00 4600 <br /> Electrical Penetration: <br /> Condition of sump prior to testing: <br /> Portion of Sump Tested 15 13 13 <br /> Sump Material Fiberglass Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5 min 5 min min <br /> test <br /> Test Start Time: 11:44:00 11:44:00 11:09:00 <br /> Initial Reading(RI): 0.00000 in.H2O 0.00000 in.H2O 0.00000 in.H2O <br /> Test End Time: 12:14:00 12:14:00 11:39:00 <br /> Final Reading(RF): -0.00090 in.H2O -0.00030 in.H2O -0.00120 in.H2O <br /> Test Duration: 30 min 30 min 30 min <br /> Change in Reading(RF RI): -0.00090 in.H2O -0.00030 in.H2O -0.00120 in.H2O <br /> Pass/Fail Threshold or Criteria: +/-0.00200 +/-0.00200 +/-0.00200 +/- <br /> 77377-- Pass, <br /> pp <br /> Test Rt .. <br /> r _ <br /> Is there a sensor in the pump? 0 Yes re No r, Yes ; No ro, Yes r No r Yes r No <br /> Does the sensor alarm when either rr Yes r Nor NA r+ Yes f Nor NA t* Yes r Nor NA r Yes r Nor NA <br /> roduct or water is detected? <br /> Was sensor removed for testing? l: Yes r Nor NA ro Yes r Nor NA ro Yes r No C NA C Yes C Nor NA <br /> Was sensor properly replaced and 0 Yes r No NA r^ ro Yes r No NA C re Yes r No NA r r Yes C No NA C <br /> verified functional after testin ? <br /> Comments-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> p � � :• .nky S �.. <br /> vtiym <br /> A0�/ry1 yy <br /> 1B 1nRG <br /> t <br /> WO:2314059 <br />
The URL can be used to link to this page
Your browser does not support the video tag.