My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:14:10 PM
Creation date
6/3/2020 9:46:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
356
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Program Inspection Report <br />Date: <br />December 19,2018 <br />Facility Address: <br />2701 W MARCH LN, STOCKTON <br />Facility Name: <br />MARCH LANE 76* <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone:(209)468-3420 Fax :(209)468-3433 Web:www.sjgov.org/ehd <br />UST System Observations <br />315 ■ V □ R ■ COSWater in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003)HSC 25291(e) <br />316 □ V □ R □ COSSecondary containment not constructed to prevent water intrusion (after Jul 2003)HSC 25290.1(c3), <br />25290.2(c3) <br />317 □ V □ R □ COSLine leak detector (LLD) not installedCCR 2636, 2643(c)(1), <br />2666(f) <br />318 □ V □ R □ COSLeak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inchCCR 2636(f)(2) <br />319 ■ V □ R □ COSNo spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be testedCCR 2635, 2637.1, <br />2665, 2712 <br />320 ■ V □ R □ COSFailure to comply with the installation, inspection, or record keeping of the overfill preventionCCR 2635, 2637.2, <br />2665, 2712 <br />321 □ V □ R □ COSOverfill prevention was overriddenCCR 2635(b)(2) <br />322 □ V □ R □ COSUnburied below grade emergency generator system failed to meet exemption statusHSC 25281.6(a) <br />323 □ V □ R □ COSUnburied below grade UST system failed to meet exemption statusHSC 25283.5(a) <br />324 □ V □ R □ COSTampered with red tagCCR 2717.1(g) <br />325 □ V □ R □ COSDeposited petroleum into a red tagged USTCCR 2717.1(f) <br />326 □ V □ R □ COSTampered with or disabled leak detection devices or alarmsHSC 25299(a)(9) <br />327 □ V □ R □ COSUST system not compatible with the substance storedCCR 2631.1 <br />328 □ V □ R □ COSFailed to comply with temporary closure requirementsHSC 25298 <br />329 □ V □ R □ COSFailed to comply with all permanent closure requirementsHSC 25298 <br />330 □ V □ R □ COSNo LLD on the emergency generator that restricts or shuts off the flow or triggers an alarmCCR 2636(f), 2666(c), <br />2666(f) <br />331 □ V □ R □ COSLiquid does not flow into the sump in the event of a leak (i.e., failure to remove test boot).CCR 2630(d), 2641(a) <br />332 □ V □ R □ COSPrimary and/or secondary containment not constructed in accordance with the established standardsCCR 2631(b&d), <br />2666(b&e) <br />333 □ V □ R □ COSFailure to comply with the cathodic protection system requirementsCCR 2635, 2636(b), <br />2662, 2712 <br />334 □ V □ R □ COSSingle-walled pipe not upgraded to double-walled interstitially monitored pipe during repairCCR 2666(b)(2) <br />335 □ V □ R □ COSEquipment or methods used to monitor the UST system are not certified by an independent third-partyCCR 2630, 2632, 2643, <br />2644.1 <br />Single-Walled Non-Pressurized Piping <br />401 □ V □ R □ COSSuction piping not properly sloped or incorrectly located check valveCCR 2636(a)(3), <br />2641(b) <br />402 □ V □ R □ COSNo monitoring or record maintenance for single-walled conventional suction systems (pre-Jan 1984).CCR 2643(d) <br />403 □ V □ R □ COSFailure to conduct 0.1 gph test for single-walled conventional suction systems (pre-Jan 1984)CCR 2643(d), 2661(f) <br />404 □ V □ R □ COSBiennial 0.1 gph line integrity test for single-walled gravity piping not performed (pre-Jan 1984)CCR 2643(e), 2661(f) <br />Other Violations <br />2010 □ V □ R □ COSUnlisted General violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Page 3 of 6 <br />FA0003798 PR0231176 SC001 12/19/2018 <br />EHD 23-01 Rev. 09/22/16 Underground Storage Tank Program OIR