My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 4:05:16 PM
Creation date
6/3/2020 9:47:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v <br />Em"ge 1101 ,a 0 0 a► _ i 1 <br />Test Method Developed By: <br />❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Specify) <br />❑ Vacuum <br />® Hydrostatic <br />Test Equipment Used: Incon Sump <br />Tester <br />Equipment Resolution: +/- 0.002" <br />UDC # 1/2 <br />UDC # 3/4 UDC # 5/6 <br />UDC # 7/8 <br />UDC Manufacturer: <br />Bravo <br />Bravo <br />Bravo <br />Bravo <br />UDC Material: <br />Steel <br />Steel <br />Steel <br />Steel <br />UDC Depth: <br />12" <br />12" <br />12" <br />12" <br />Height from UDC Bottom to Top <br />of Hi hest Piping Penetration: <br />Located on Bottom <br />Located on Bottom <br />; Located on Bottom <br />Located on Bottom <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />Located on Bottom <br />Located on Bottom <br />Located on Bottom <br />Located on Bottom <br />Condition of UDC prior to <br />testing: <br />Good <br />Good <br />Good <br />Good <br />I <br />Portion of UDC Tested <br />2" above piping <br />2" above piping <br />2" above piping <br />2" above piping <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />roduct and water)?` <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ®NA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?' <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ®NA <br />Was fail-safe verified to be <br />o erational?ce <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />30 minutes <br />30 minutes <br />30 minutes <br />i 30 minutes <br />Test Start Time: <br />2:31 pm <br />2:31 pm <br />2:12 pm <br />2:12 pm <br />Initial Reading (Rj): <br />5.3948 <br />4.3248 <br />4.7747 <br />3.2505 <br />Test End Time: <br />2:46 pm <br />2:46 pm <br />2:27 pm <br />2:27 pm <br />Final Reading (RF): <br />5.3948 <br />4.3252 <br />4.7753 <br />3.2506 <br />Test Duration: <br />15 min. <br />15 min. <br />15 min. <br />15 min. <br />Change in Reading (RF -RI): <br />0.0000 <br />0.0004 <br />0.0006 <br />0.0001 <br />Pass/Fail Threshold or Criteria: <br />+/-0.002" <br />+/- 0.002" <br />+/- 0.002" <br />+/-0.00213 <br />Test Results <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass 0 Fail <br />® Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No M NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®yes ❑ No ®NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testis scope of work".H I'm �— IVE.DN a WMEM -*,o &%Mm <br />NEW& MEN= <br />FFF'S' 11 2A1 <br />011 ("I1lInnRlTAI Ao r <br />D. <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to ant% of the questions indicated with an <br />asterisk(*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.