My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_2013-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2024 4:22:39 PM
Creation date
6/3/2020 9:54:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2014
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_2013-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
358
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W <br />San Joaquin County ucunen <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 j <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />w q , <br />/My <br />Y <br />Facility Name: Facility Address: <br />Date: <br />Tracy Valero 2375 N TRACY BLVD, TRACY <br />September 29, 2014 <br />V i4y�p <br />c iwi-1 orna e' , <br />Item # <br />Remarks <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to check and note the correct test dates for the annual monitoring certification testing <br />and the secondary containment testing on the November 2013 through July 2014 designated operator monthly <br />inspection reports. These nine inspection reports all note that test results are needed. The dates are listed on the <br />August 2014 and September 2014 inspection reports. During the monthly inspection, the designated operator shall <br />check that all required testing and maintenance for the UST system have been completed and document the dates they <br />were done. Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. This is a repeat violation, Class Il. <br />The designated operator failed to document all the alarms from the alarm history, and to attach an alarm history, on the <br />November 2013 through September 2014 designated operator monthly inspection reports, and failed to check that all <br />alarms were responded to appropriately. The alarm history printed by the technician at the time of inspection only goes <br />back to the cold start performed on November 25, 2013. Alarms prior to the cold start were not available. The <br />designated operator is not printing out an alarm history, but is instead using alarm printouts kept by the site from alarms <br />throughout the month. These records are incomplete. All sensors were set into alarm on 11/25/13 and 1/22/14; the <br />designated operator monthly reports for November and January note only the L4 alarms. The November report did not <br />include the date of the alarm. Neither report indicated the type of alarm (sensor out, fuel, etc.). The missing alarms <br />from the alarm history provided at the time of inspection also include: C1 (UDC 1/2) fuel alarms on 1/30/14 and 4/25/14, <br />and L4 (91 annular sensor) sensor out alarms on 8/1/14, 8/3/14, 9/14/14. The missing alarms from the site alarm logs <br />include sensor out alarms on November 14, 15, 16, 17, 19, and 21, 2013. The alarm logs do not state which sensor <br />was in alarm. No alarms are noted on the December 2013, and February 2014 through September 2014 monthly <br />inspection reports. During the monthly inspection, the designated operator shall review the alarm history for the <br />previous month, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br />history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br />performing monthly inspections at this facility are including all of the required information on the reports. This is a repeat <br />violation, Class ll. <br />208 <br />CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months. <br />The September 2013 and October 2013 designated operator monthly inspection reports were not found on site. <br />Designated operator monthly inspection reports for the previous twelve months shall be retained on site. Locate and <br />ensure that copies of the previous twelve months of designated operator monthly inspection reports are maintained on <br />site. Submit copies to the EHD. This is a repeat violation, Class ll. <br />209 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training for Rajinder Kaur was not performed. The only training record found on site <br />was for Rupinder Kaur, dated August 14, 2014. The designated operator shall train facility employees for which he or <br />she is responsible in the proper operation and maintenance of the UST system once every 12 months. The training <br />shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of the <br />training records to the EHD. This is a repeat violation, Class II. <br />Received by (initial): <br />Inspector: <br />Phone: <br />Date: <br />Itul %d <br />I STACY RIVERA, Senior REHS <br />(209) 468-3440 <br />09/29/2014 <br />Page 6 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.