My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FILE 12
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_FILE 12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 4:43:06 PM
Creation date
6/3/2020 9:55:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 12
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_FILE 12.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
472
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
09/22/05 11:04 FAX 925 422 2748 EPD / WGMG IM005 <br /> SWRCB,January 2002 FINAL DRAFT Page.--A_of 7 <br /> 5. MING SUMP TESTING <br /> Test Method Developed By: El sump Manufacturer 0 Industry Standard 0 Professional Engineer <br /> ElOther(Specify) <br /> Test Method Used: 0 Pressure El vacuum 9 Hydrostatic <br /> F1 Other(Specify) <br /> Test Equipment Used: Caldwell Sump Level Change Indicator Equipment Resolution: 0.0025" <br /> R <br /> z <br /> kNR <br /> k_ sump# sump# Sump# —sunp# <br /> 882-DIU2 <br /> Sump Diameter: 36.0" <br /> Sump Depth from Top of Tank- 36.0,, <br /> Sump Material: FRP <br /> Height from Tank Top to Top of 17.75" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Top of 15 5" <br /> Lowest Electrical Penetration: <br /> Condition of sump prior to testing: Cleao/Dry <br /> Depth of Sump Tested' 19.75" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both Elyes ONo®NA ElYes E]NoE]NA ❑E-Wes❑FlNoEINA []Yes[:]NoE]NA <br /> product and water)? <br /> Turbine shutdown response time- Suction System <br /> Is system programmed for fail-safe <br /> shutdown,?* []Yes E]No®NA [—]Yes E]No FINA E]Yes EjNo EINA []Yes EjNo MNA <br /> Was fail-safe verified to be <br /> ®Yes Yes E]No ZNA E]Yes[:]No❑NA E]Yes[]No ONA []Yes E]No ONA <br /> Wait time between applying <br /> I pressure/vacuum/water and starting 10 minutes <br /> test: <br /> Test Start Time: 8:28am. <br /> Initial Reading ft 19.75" <br /> Test End Time: 9:13am <br /> Final Reading(RF): 19-75" <br /> Test Duration: 45 minutes <br /> Change in Reading(R4,Rj): 6.00'= ------— <br /> Pass/Fail Threshold or Criteria: 0.00", <br /> a', <br /> .:fFass Gail QP, <br /> Was sensor removed for testing? ®Yes ONo EINA ElYes E]No[-INA OYes E]No[INA L]Yes E]No EINA_ <br /> Was sensor properly replaced and ®Yes nNo nNA Oyes ONo EINA E]Yes nNo[]NA OYes ONo[INA <br /> verified functional after testing? I I I <br /> Comments—(Include information on repairs made prior to testing,and recommended UJT!tup for failed tests.) <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to My of the questions indicated with an <br /> asterisk(*)is"W,than the entire sump should he tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.