Laserfiche WebLink
0CONTINUATION FORM Page: 4 of 5 <br /> FFICIAL INSPECTION REPORT 10 Date: 4/8/08 <br /> Facility Address: Program: UST <br /> 27 Annual line tightness test: CCR 2636 (f)(4) <br /> At time of inspection the following float and chain mechanisms in the UDC's were inoperable. <br /> UDC 7/8 Middle float broken <br /> UDC 11 Both floats did not work UDC 15 ( ) float did not work <br /> UDC 12 Both floats did not work UDC 16 (W) float did not work <br /> UDC 13 Both floats did not work Gas dispenser at ( ) end of Truck Stop, both <br /> UDC 14 Both floats did not work floats did not work <br /> Continuous monitoring systems that either activates an audible and visual alarm or stops the <br /> flow of product at the dispenser when it detects a leak, satisfy the annual line tightness testing <br /> requirement if both of the following conditions are met: <br /> ) The monitoring system shuts down the pump or stops the flow of product at the dispenser <br /> when a leak is detected in the UDC. <br /> The monitoring system for all product piping other than that contained in the UDC is fail safe <br /> and shuts down the pump when a leak is detected. <br /> Within 30 days of receipt of this inspection report a line test must be performed on all lines that <br /> did not have continuous monitoring that fulfilled both requirement A and B listed above. Within <br /> 30 days of line test, results must be submitted to this office. <br /> 32 Permit to repair UST system: CCR 2661 <br /> -At time of inspection the 87 spill bucket was not tested, failed by tester before lake test due to <br /> broken rim on 87 spill bucket, Diesel East spill bucket failed 1 hour lake test, and 87 and 91 leak <br /> detectors failed to detect a 3.Ogph @10PSI leak. <br /> -At time of inspection the following float and chain mechanisms in the UDC's were inoperable. <br /> UDC 7/8 Middle float broken <br /> UDC 11 Both floats did not work UDC 15 (E) float did not work <br /> UDC 12 Both floats did not work UDC 16 (W) float did not work <br /> UDC 13 Both floats did not work Gas dispenser at ( ) end of Truck Stop, both <br /> UDC 14 Both floats did not work floats did not work <br /> - t time of inspection it was discovered that dispensers had been changed approximately 6-9 <br /> months previously (Per CJ Jutla). Dispensers are larger than the UDC's, thus if there were a leak <br /> from the primary piping the UDC may not contain it. <br /> The UST system shall be designed and constructed with a monitoring system capable of <br /> detecting the entry of hazardous substance stored in the primary into the secondary <br /> containment. <br /> Permits must be obtained from this office for the previously listed failures and unapproved <br /> installations, Immediately. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> EHD Ins t Received By: Title: <br /> S JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT*600 E MAIN STREET, STOCKTON,CA 95202 (209)468-3420 <br />