Laserfiche WebLink
REC'D JUL 2'0 2015 <br />7. ER -DISPENSER CONTAINMENT C TESTING <br />Test Method Developed By: ❑ UDC Manufacturer El Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: See attached testing procedures Equipment Resolution: Inches <br />01111122111 <br />UDC # 3/4 UDC # 5/6 UDC # 7/8 <br />UDC Manufacturer: <br />730"730" <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />30" <br />30" <br />Height from UDC Bottom to Top <br />8" <br />of Highest Piping Penetration: <br />8" <br />8" <br />8" <br />Height from UDC Bottom to <br />5" <br />Lowest Electrical Penetration: <br />5" <br />5" <br />5" <br />Condition of UDC prior to <br />Fair <br />testing: <br />Fair <br />Fair <br />Fair <br />Portion of UDC Tested Above highest penetration <br />Above highest penetration <br />Above highest penetration <br />Above highest penetration <br />Does turbine shut down when <br />UDC sensor detects liquid (both N/A <br />N/A <br />N/A <br />N/A <br />product and water)?* <br />Turbine shutdown response time N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?' ❑ Yes ❑ No Q NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />fail-safe <br />Was fail-safe verified to be <br />operational?* ❑ Yes ❑ No p NA <br />❑ Yes ❑ No p NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No p NA <br />Wait time between applying <br />pressure/vacuum/water and 15 minutes <br />15 minutes <br />15 minutes <br />15 minutes <br />starting test <br />Test Start Time: 12:19pm <br />12:19pm <br />11:51 am <br />11:51 am <br />Initial Reading Ri): 1.39166 Inches <br />1.00058 Inches <br />0.16165 Inches <br />1.53780 Inches <br />Test End Time: 12:34pm <br />12.34pm <br />12.06pm <br />12:06pm <br />Final Reading (RF): 1.39152 Inches <br />0.99997 Inches <br />0.16176 Inches <br />1.53780 Inches <br />Test Duration: 15 mins <br />15 mins <br />15 mins <br />15 mins <br />Change in Reading (RF -RI): 0.00014 <br />0.00061 <br />0.00011 <br />0.00000 <br />Pass/Fail Threshold or Criteria: .002 <br />.002 <br />.002 <br />.002 <br />Test Result: p Pass ❑ Fail <br />p Pass ❑ Fail <br />p Pass ❑ Fail <br />p Pass ❑ Fail <br />Was sensor removed for testing? ® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />® <br />verified functional after testin ? Yes ElNo p NA p Yes ❑ No ❑ NA I ®Yes ❑ No ❑ NA p Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />