My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3355
>
2300 - Underground Storage Tank Program
>
PR0508352
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2021 9:09:56 AM
Creation date
6/3/2020 9:59:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0508352
PE
2361
FACILITY_ID
FA0008044
FACILITY_NAME
CHEVRON STATION #1731*
STREET_NUMBER
3355
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12618007
CURRENT_STATUS
01
SITE_LOCATION
3355 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508352_3355 E HAMMER_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. <br />ER -DISPENSER CONTA NT C TESTING <br />Test Method Developed By: <br />❑ UDC Manufacturer Q Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: <br />❑ Pressure <br />❑ Vacuum <br />® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: see attached testing procedures <br />Equipment Resolution: Inches <br />EMUDC <br /># 9/10 <br />UDC # 11:12 <br />UDC # UDC # <br />UDC Manufacturer: <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />30" <br />30" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />8" <br />8" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />5" <br />5, <br />Condition of UDC prior to <br />testing: <br />Fair <br />Fair <br />Fair Fair <br />Portion of UDC Tested <br />Above highest penetration <br />Above highest penetration <br />Above highest penetration Above highest penetration <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />N/A <br />N/A <br />N/A N/A <br />product and water)?* <br />Turbine shutdown response time <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?" <br />❑ Yes ❑ No p NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ® NA ❑ Yes ❑ No ®NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑ No Q NA <br />❑ Yes ❑ No p NA <br />❑ Yes ❑ No ®NA ❑ Yes ❑ No p NA <br />Wait time between applying <br />pressure/vacuum/water and <br />15 minutes <br />15 minutes <br />15 minutes 15 minutes <br />starting test <br />Test Start Time: <br />11:28am <br />11:28am <br />Initial Reading (RI): <br />4.91992 Inches <br />0.06746 Inches <br />Inches Inches <br />Test End Time: <br />11:43am <br />11:43am <br />Final Reading (RF : <br />4.92064 Inches <br />0.06783 Inches <br />Inches Inches <br />Test Duration: <br />15 mins <br />15 mins <br />15 mins 15 mins <br />Chane in Reading (RF -RI): <br />0.00072 <br />0.00037 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 <br />Test Result: <br />Q Pass ❑ Fail <br />Q Pass ❑ Fail <br />❑ Pass ❑ Fail ❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ NO ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior <br />to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.