My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
824
>
2300 - Underground Storage Tank Program
>
PR0231459
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2020 7:06:55 PM
Creation date
6/11/2020 10:34:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231459
PE
2361
FACILITY_ID
FA0003677
FACILITY_NAME
DIAMOND GAS AND FOOD MART
STREET_NUMBER
824
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118003
CURRENT_STATUS
01
SITE_LOCATION
824 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for DIAMOND GAS AND FOOD MART as of May11, 2020 . <br /> Open violations from June 04 , 2019 inspection <br /> Violation #124 - " Overfill Prevention Equipment Inspection Report Form" not submitted within 30 days of <br /> inspection . <br /> Overfill prevention equipment inspection report was performed on 10/9/18 . An Overfill prevention equipment <br /> inspection report form was submitted to the EHD in January 2019 , over two months late . A copy of the test report <br /> must be submitted within 30 days of the test . Ensure test results are submitted within 30 days from the day of <br /> testing . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #201 - Failure to maintain monitoring , maintenance , and follow up action records . <br /> Maintenance and monitoring records for the last three years were not found on site . Overfill prevention equipment <br /> inspection results , Record for L4 - 89 STp fuel alarm on 6/16/18 . These records shall be maintained on site for at <br /> least three years . Monitoring records include : ( 1 ) date and time of all monitoring or sampling ; (2 ) monitoring <br /> equipment calibration and maintenance records ; (3 ) results of any visual observations ; (4 ) results of sample analysis <br /> performed a lab or in the field ; (5 ) logs of all readings of gauges or other monitoring equipment, ground water <br /> elevations , or other test results ; (6 ) results of inventory readings and reconciliations . Immediately locate and <br /> maintain all maintenance and monitoring records for the last three years on site and submit copies to the EHD . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #202 - Failure to maintain the " Facility Employee Training Certificate" on-site (after October 1 , <br /> 2018 ) . <br /> " Facility Employee Training Certificate" dated 2/28/19 was found on site without the signature from the Designated <br /> Operator, Furhtermore Noorullah Fnu and Manpreet Singh started working in the facility in May 2019 and April 2019 <br /> and are yet to be trained byt the DO . All site employees must be trained prior to taking responsibility as a facility <br /> employee if after October 1 , 2018 , or within 30 days of hire if prior to October 1 , 2018 . The " Facility Employee <br /> Training Certificate" shall contain accurate information for all employees trained . Update the " Facility Employee <br /> Training Certificate" to contain the accurate information and submit a copy of the updated form to the EHD . <br /> Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.