My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2057
>
2300 - Underground Storage Tank Program
>
PR0231083
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2020 11:55:06 AM
Creation date
6/23/2020 6:41:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231083
PE
2361
FACILITY_ID
FA0003735
FACILITY_NAME
QUICK N EASY MART
STREET_NUMBER
2057
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16515309
CURRENT_STATUS
01
SITE_LOCATION
2057 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231083_2057 S EL DORADO_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY 0 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />CONTINUATION FORM <br />Page: 4 of 5 <br />OFFICIAL INSPECTION REPORT <br />Date: 04/07/14 <br />Facility Address: 2057 S. EI Dorado St., Stockton <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS 1, CLASS II, or MINOR -Notice to Comply) <br />107. A plot plan / monitoring site map is not submitted in CERS. All monitoring programs shall include <br />the location(s), as identified on a plot plan, where the monitoring will be performed. Immediately log into <br />CERS, update the required information, and submit for review by the EHD. <br />201. Monitoring and maintenance records were not found on site for the cold start inspection <br />conducted on September 4, 2013 or the alarm noted in the alarm history for the 87 STP sensor on <br />February 28, 2014. These records shall be kept on site for at least 3 years. Immediately locate and <br />maintain the maintenance and monitoring records on site and submit copies to the EHD by May 7, 2014. <br />202. A copy of the 2014 UST operating permit was not found on site. A copy of the UST operating <br />permit and all attachments and conditions shall be retained at the facility. Immediately obtain a copy of <br />the permit and retain it on site. REPEAT VIOLATION <br />204. The designated operator failed to check and note the correct test dates for the SB989 (triennial <br />secondary containment) testing on the designated operator monthly inspection reports. The test date is <br />documented on the reports as November 1, 2012; according to EHD records, this testing took place on <br />April 10, 2013. During the monthly inspection, the designated operator shall check that all required <br />testing and maintenance for the UST system have been completed and document the dates they were <br />done. Ensure that designated operators performing monthly inspections at this facility are including all <br />of the required information on the reports. <br />205. The April, August, September, October, November, December 2013 and January, February, and <br />March 2014 designated operator monthly inspection reports were not found on site. Alarm history <br />printouts for these months were found in the designated operator binder on site. Designated operator <br />monthly inspection reports for the previous twelve months shall be retained on site. Locate and ensure <br />that copies of the previous twelve months of designated operator monthly inspection reports are <br />maintained on site. Submit copies to the EHD by May 7, 2014. REPEAT VIOLATION <br />303. The 87 wrap-around annular sensor was tested and passed at the time of inspection, however the <br />technician could not get the sensor back in the tank. The 87 annular sensor is currently not located at <br />the bottom of the tank to detect a leak at the earliest opportunity. Monitoring equipment shall be <br />maintained to be able to detect a leak at the earliest possible opportunity. Immediately contact a <br />properly licensed, trained, and certified contractor to relocate this sensor to the lowest point of the 87 <br />tank. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Stacy Rivera (209) 468-3440 <br />Re ived By: <br />V y 1z <br />Title: <br />EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.