E <br />6. Piping Sump Testing <br />Test Method Developed By: ❑ Tank Manufacturer <br />Test Method Used: ❑ Pressure <br />Test Equipment Used: Incon TS STS Leak Detector <br />11 <br />0 Industry Standard ❑ Professional Engineer <br />❑ vacuum ❑X Hydrostatic <br />Equipment Resolution: ±0.002 <br />Comments: <br />4 of 7 <br />Sump # 87 <br />Sump # 89 <br />Sump # 91 <br />Sump # <br />Sump Diameter: <br />42" <br />42" <br />42" <br />Sump Depth: <br />Sump <br />Sum Material <br />� <br />52" <br />-----� <br />51" <br />51" <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />17 <br />�— <br />18" <br />Highest Piping Penetration: <br />1 16" <br />Height from Tank Top to Lowest <br />�— <br />�— <br />Electrical Penetration: <br />22„ <br />18" <br />17" <br />Condition of sump prior to testing: <br />ok <br />ok <br />ok <br />Portion of Sump Tested <br />Does turbine shut down when <br />20" <br />-- <br />21" <br />-- <br />1g, <br />i <br />— <br />-- <br />sump sensor detects liquid (both <br />product and water)?' <br />Yes <br />NA <br />0 Yes <br />0 N—o— <br />NA <br />Yes 0No 4 NA <br />0 Yes 0 No <br />NA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />fIs system programmed for fail-safe <br />shutdown?' <br />0 Yes <br />0 No <br />NA <br />0 Yes <br />0 No <br />(0 NA <br />0 Yes 0 No NA <br />0 Yes 0 No <br />0 NA j <br />Was fail-safe verified to be <br />operational? <br />0 Yes <br />0 No <br />NA <br />0 Yes <br />0 No <br />© NA <br />0 Yes 0 No 0 NA <br />0 Yes 0 No <br />0 NA <br />Wart time: <br />15 min <br />15 min <br />15 min <br />---- -- ---- <br />1:40 <br />2:33 <br />3:03 <br />----_ <br />Test Start Time: <br />Initial Reading: <br />1.2745 <br />3.8252 <br />3.9543 <br />Test End Time: <br />1:55 <br />2:48 <br />3:18 <br />Final Reading: <br />1.2749 <br />3.8251 <br />3.9540 <br />; Test Duration (hh:mm) : <br />I <br />00:15 <br />00:15 <br />00:15 <br />00:00 <br />T- <br />—� <br />i Change in Reading: j <br />0.0004 <br />� <br />0.0001 <br />� <br />-0.0003 <br />L— 0.0000 <br />1 <br />Pass/Fail Threshold or Criteria: <br />±0.002 <br />±0.002 <br />±0.002 <br />±0.002 <br />Test2es�iitass <br />0 "Frl• Pais ) fir! <br />Ps" <br />Was sensor removed for testing?Q <br />Yes <br />0 No�O <br />NA Yes <br />0 No <br />0 NA j <br />(S Yes 0 No 0 NA <br />0 Yes 0 No <br />0 NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />0 Yes <br />0 No <br />0 NA Yes <br />0 No <br />0 NA <br />Yes 0 No 0 NA <br />0 Yes 0 No <br />0 NA <br />Comments: <br />4 of 7 <br />