My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2021 3:02:45 PM
Creation date
6/23/2020 6:43:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231125_1210 E HAMMER_2011-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
318
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />6. Piping Sump Testing <br />Test Method Developed By: ❑ Tank Manufacturer <br />Test Method Used: ❑ Pressure <br />Test Equipment Used: Incon TS STS Leak Detector <br />11 <br />0 Industry Standard ❑ Professional Engineer <br />❑ vacuum ❑X Hydrostatic <br />Equipment Resolution: ±0.002 <br />Comments: <br />4 of 7 <br />Sump # 87 <br />Sump # 89 <br />Sump # 91 <br />Sump # <br />Sump Diameter: <br />42" <br />42" <br />42" <br />Sump Depth: <br />Sump <br />Sum Material <br />� <br />52" <br />-----� <br />51" <br />51" <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />17 <br />�— <br />18" <br />Highest Piping Penetration: <br />1 16" <br />Height from Tank Top to Lowest <br />�— <br />�— <br />Electrical Penetration: <br />22„ <br />18" <br />17" <br />Condition of sump prior to testing: <br />ok <br />ok <br />ok <br />Portion of Sump Tested <br />Does turbine shut down when <br />20" <br />-- <br />21" <br />-- <br />1g, <br />i <br />— <br />-- <br />sump sensor detects liquid (both <br />product and water)?' <br />Yes <br />NA <br />0 Yes <br />0 N—o— <br />NA <br />Yes 0No 4 NA <br />0 Yes 0 No <br />NA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />fIs system programmed for fail-safe <br />shutdown?' <br />0 Yes <br />0 No <br />NA <br />0 Yes <br />0 No <br />(0 NA <br />0 Yes 0 No NA <br />0 Yes 0 No <br />0 NA j <br />Was fail-safe verified to be <br />operational? <br />0 Yes <br />0 No <br />NA <br />0 Yes <br />0 No <br />© NA <br />0 Yes 0 No 0 NA <br />0 Yes 0 No <br />0 NA <br />Wart time: <br />15 min <br />15 min <br />15 min <br />---- -- ---- <br />1:40 <br />2:33 <br />3:03 <br />----_ <br />Test Start Time: <br />Initial Reading: <br />1.2745 <br />3.8252 <br />3.9543 <br />Test End Time: <br />1:55 <br />2:48 <br />3:18 <br />Final Reading: <br />1.2749 <br />3.8251 <br />3.9540 <br />; Test Duration (hh:mm) : <br />I <br />00:15 <br />00:15 <br />00:15 <br />00:00 <br />T- <br />—� <br />i Change in Reading: j <br />0.0004 <br />� <br />0.0001 <br />� <br />-0.0003 <br />L— 0.0000 <br />1 <br />Pass/Fail Threshold or Criteria: <br />±0.002 <br />±0.002 <br />±0.002 <br />±0.002 <br />Test2es�iitass <br />0 "Frl• Pais ) fir! <br />Ps" <br />Was sensor removed for testing?Q <br />Yes <br />0 No�O <br />NA Yes <br />0 No <br />0 NA j <br />(S Yes 0 No 0 NA <br />0 Yes 0 No <br />0 NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />0 Yes <br />0 No <br />0 NA Yes <br />0 No <br />0 NA <br />Yes 0 No 0 NA <br />0 Yes 0 No <br />0 NA <br />Comments: <br />4 of 7 <br />