SWRCB, January 2002 <br />6. PIPING SUMP TESTING <br />Page _4_ of —7— <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: INCON TS - STS <br />Equipment Resolution: 0.002" <br />Sump # 87 Sump # 91 <br />Sump # DSL Sump # <br />Sump Diameter: <br />48" 48" <br />48" <br />Sump Depth: <br />48" <br />51" <br />55" <br />Sump Material: <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />Height from Tank Top to Top of <br />34" <br />38" <br />41" <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />25" <br />24" <br />25" <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />GOOD <br />GOOD <br />GOOD <br />Portion of Sump Tested' <br />ABOVE <br />ABOVE <br />ABOVE <br />PENETRATION <br />PENETRATION <br />PENETRATION <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No Z NA <br />❑ Yes ❑ No ® NA <br />[]Yes ❑No [INA <br />product and water)?* <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail-safe <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes [:]No ®NA <br />[]Yes ❑ No [INA <br />shutdown?` <br />Was fail-safe verified to be <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />[]Yes ❑ No ❑ NA <br />operational?" <br />Wait time between applying <br />pressure/vacuum/water and starting <br />15 MIN <br />15 MIN <br />15 MIN <br />test: <br />Test Start Time: <br />10:07 AM <br />10:07 AM <br />10:07 AM <br />Initial Reading (RI): <br />5.9840" <br />4.2988" <br />5.1997' <br />Test End Time: <br />11:22 AM <br />11:22 AM <br />11:22 AM <br />Final Reading (RF): <br />5.9838" <br />4.2984" <br />5.1997' <br />Test Duration: <br />15 MIN <br />15 MIN <br />15 MIN <br />Change in Reading (RF -RI): <br />- 0.0002" <br />- 0.0004" <br />0.0000" <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/- 0.002" <br />+/-0.00211 <br />Tent Result: <br />Pass ❑ Fail0?As�No <br />❑ Fail <br />Z Pass El Fail <br />,0:P#4 ❑Fail <br />Was sensor removed for testing? <br />®Yes ❑ No ❑ NA <br />®Yes ❑NA <br />® Yes ❑ No ❑ NA <br />[:]Yes ❑ No ❑ NA <br />Ljwa�,S_ sensor properly replaced and <br />®Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes [:]No ❑NA <br />[]Yes ❑No ❑ NA <br />fied functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS. <br />SENSORS WERE NOT TESTED DUE TO ANNUAL MONITOR CERTIFICATION. <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />