Laserfiche WebLink
Tait Environmental Services <br />USTConstruction • Design • Maintenance • Compliance <br />E <br />Facility Name: AT&T Corporation Lodi: LODICA02 CAK482 <br />Date: 02/22/2008 <br />Facility Address: J110 W. Turner Rd. <br />1 <br />City: Lodi <br />1ZiP Code: 95242 <br />Designated UST Operator Conducting the Inspection: Koffel Georc e <br />International Code Council Certification #: 5247982 -UC <br />Expiration Date: 12/19/2008 <br />Signature <br />Phone: 714-920-5387 <br />Item <br />MONITORING PANEL / ALARM HISTORY <br />1 <br />Monitoring system is powered on and in operating mode <br />Yes <br />2 <br />Monitoring system is not currently showing any alarms or wamin s <br />Yes <br />3 <br />Alarm history reportilog for the previous month is available, and has been reviewed by the <br />Desi nated UST Operator Attach a copy of the alarm history report/logreport/log to this form if available <br />Yes <br />4 <br />Each alarm for the previous month has been responded to appropriately. <br />Yes <br />5 <br />Sensors located in tank -top containment sumps have not alarmed in theast month. <br />INo <br />5a <br />List all tank -top sumps where alarms occurred in the past month: See comments. <br />Note: Sumps where an alarm has occurred in the past month must be inspected unless a qualified technician responded to, and properly <br />addressed, the cause of the alarm. Attach documentation verifying appropriate service to this report. If sump inspection is required, record <br />results in item 6 below. <br />UST SYSTEM INSPECTION <br />6 <br />Tank -top containment sumps are free of water, debris, and hazardous substance. Sensors are located properly. <br />Note: Visual inspection of sums is only required in sums where an alarm has occurred in the past month for which there Is no service record <br />YIN I Deb I Lip <br />YIN I Deb Li <br />Sump Location: Sump Location: <br />Sump Location: SumD Location: <br />Sump Location: Sump Location: <br />7 <br />Spill containment structures are free of water, debris and hazardous substance. <br />Tank 1 - Contents: Diesel <br />Yes <br />Tank 3 - Contents: <br />N/A <br />Tank 2 - Contents: <br />N/A <br />Tank 4 - Contents: <br />N/A <br />8 <br />Under -dispenser containment areas are free of water, debris, and hazardous substance. Sensors are located <br />ro erl . <br />Dispenser 1/2 <br />N/A <br />Dispenser 9/10 <br />N/A <br />Dispenser 3/4 <br />N/A <br />Dispenser 11/12 <br />N/A <br />Dispenser 5/6 <br />N/A <br />Dispenser 13/14 <br />N/A <br />Dispenser 7/8 <br />N/A <br />Dispenser 15/16 <br />N/A <br />PAPERWORK INSPECTION <br />DATE DONE <br />9 <br />Monitorin system certification has been completed within past 12 months. Yes <br />07/13/2007 <br />10 <br />Seconds containment tests have been completed within the required timeframe. Yes 07/18/2005 <br />11 <br />Spill containment structure bucket testing was completed within the past year. Yes 07/13/2007 <br />12 <br />Tank tightness testing was completed within required timeframe. N/A <br />13 <br />Line ti fitness testing was completed within required timeframe. N/A <br />14 <br />Other required testing/maintenance was completed within required timeframe. List test/maintenance items below. <br />Test/Maintenance: Monitoring system certification new TLS Yes 01/28/2008 <br />T@SUMaintenance: Spill bucket testin news ill bucket Yes 01/28/2008 <br />Test/Maintenance: N/A <br />