My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:56:31 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> e-LL_ <br /> SWRCB,January 2002 <br /> 6. PIPING SUMP TESTING JUL 2 0 2016 <br /> Test Method Developed By: ❑Sump Manufacturer ®Industry Standard ❑Profession4 <br /> ❑Other(Specify) .��..._.. .- <br /> Test Method Used: ❑Pressure ❑Vacuum 0 Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Incon TS-STS Equipment Resolution: .0006 <br /> U E046 U 002 <br /> Sump Diameter: 44" <br /> _......----...------- <br /> -Sump Depth: 56" <br /> Sump Material: Fiberglass <br /> Height from Tank Top to Top of 20" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 15" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Good <br /> Portion of Sump Tested' 2"above high pen. <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No ONA Dyes❑No❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA <br /> product and water)?" <br /> Turbine shutdown response time NA <br /> Is system programmed for fail-safe ❑Yes [—]No [ENA <br /> ❑ <br /> shutdown?` ❑ ❑ ❑ ❑ ❑ <br /> Yes❑No NA Yes❑No NA Yes No❑NA <br /> Was fail-safe verified to be E]Yes ❑No ®NA <br /> operational?` ❑Yes❑No❑NA ❑Yes❑No ❑NA ❑Yes❑No❑NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 min. <br /> test: <br /> Test Start Time: 10:31 am 10:47 am <br /> Initial Reading(Rj): 2.6053 2.6055 <br /> Test End Time: 10:46 am 11:02 am <br /> Final Reading(RF): 2.6054 2.6054 <br /> Test Duration: 15 min. 15 min. <br /> Change in Reading(RF-RI): .0001 .0001 <br /> Pass/Fail Threshold or Criteria: .002 .002 <br /> Test Result: El Pass ❑Fail ❑ Pass ❑Fail ❑Pass ❑Fail ❑Pass E]Fail <br /> Was sensor removed for testing? [E]Yes ❑No [_]NA ❑Yes❑No❑NA ❑Yes❑No [_]NA [—]Yes❑No❑NA <br /> Was sensor properly replaced and [—]Yes ❑X No [_]NA <br /> verified functional after testing? ❑Yes❑No®NA ❑Yes❑No ❑NA ❑Yes❑No❑NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> The sensor was reinstalled to the lowest point, but not tested. <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to aM of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.