Laserfiche WebLink
SWRCB, January 2002 0 Page _4_ of —8- <br />6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: INCON SUMP TESTER Equipment Resolution: + / - 0.002" <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br />SENSOR FUNCTIONALITY WAS NOT CONFIRMED. THIS PROCEDURE IS NOT A PART OF SB989 TESTING. <br />87 MAIN FAILED - RAN TWO 15 MINUTE TESTS ABOVE COLLAR - FAILED - NEED TO FIBERGLASS COLLAR <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk M is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Sump # 87 MAIN <br />Sump # 87SYPHON <br />Sump # 91 <br />Sump # <br />48" <br />48" <br />48" <br />Sump Diameter: <br />Sump Depth: <br />50" <br />55" <br />60" <br />Sump Material: <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />Height from Tank Top to Top of <br />127" <br />28" <br />30" <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />12" <br />14" <br />12" <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />FAIR <br />FAIR <br />FAIR <br />Portion of Sump Tested' <br />2" ABOVE <br />2" ABOVE <br />2" ABOVE <br />PENETRATION <br />PENETRATION <br />PENETRATION <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />❑ Yes []No ❑ NA <br />product and water)?` <br />Turbine shutdown response time <br />N/A <br />NIA <br />N/A <br />Is system programmed for fail-safe <br />❑ yes [:]No ®NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ® NA <br />❑ Yes [:]No ❑ NA <br />shutdown?* <br />Was fail-safe verified to be <br />❑ [:1Yes No ®NA <br />El Yes ElNo ®NA <br />❑Yes ❑ No ®NA <br />[:]Yes❑ No ❑ NA <br />operational? <br />Wait time between applying <br />pressure/vacuum/water and starting <br />30 MIN <br />30 MIN <br />30 MIN <br />test: <br />Test Start Time: <br />1:16 PM <br />3:02 PM <br />3:02 PM <br />Initial Reading (Rj): <br />6.6199" <br />7.3382" <br />6.0710" <br />Test End Time: <br />1:31 PM <br />3:17 PM <br />3:17 PM <br />Final Reading (RF): <br />6.4672" <br />7.3377' <br />6.0711" <br />Test Duration: <br />15 MIN <br />15 MIN <br />15 MIN <br />Change in Reading (RF -RI): <br />- 0.1527' <br />- 0.0005" <br />0.0001" <br />Pass/Fail Threshold or Criteria: <br />+ / - 0.002" <br />+ / - 0.002" <br />+/-0.00211 <br />+ / - 0.002" <br />Test Result: <br />® Pass 0 Fail <br />0 Pass ❑ Fail <br />[D Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />®Yes [--]No ❑NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No []NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />®Yes ❑ No [:1 NA <br />®Yes [:1 No El NA <br />®Yes ❑ No ❑ NA <br />El Yes El No El NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br />SENSOR FUNCTIONALITY WAS NOT CONFIRMED. THIS PROCEDURE IS NOT A PART OF SB989 TESTING. <br />87 MAIN FAILED - RAN TWO 15 MINUTE TESTS ABOVE COLLAR - FAILED - NEED TO FIBERGLASS COLLAR <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk M is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />