My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 10:45:06 AM
Creation date
6/23/2020 6:57:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County 1W MENDED <br />Environmental Health Department 'j <br />1868 East Hazelton Avenue, Stockton, California 95205-6232"- <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: <br />Ulta Storage Tank a!WotQn Report <br />Facility Name: Facility Address: Date: <br />FLYING J TRAVEL PLAZA A618* 1501 N JACK TONE RD RIPON May 04 2016 <br />SUMMARY OF V f ,-s <br />(GLASS F, GLASS 11, or#AtN0R -Notice to Comply) <br />Item # <br />Remarks <br />106 <br />CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />The monitoring plan is not current and/or not approved by the EHD. The monitoring plan for the onsite oil water <br />separator indicates that the leak alarm triggers the automatic pump shut down and failure or disconnection of the <br />sensor also triggers an automatic pump shut down. The monitoring plan must be uploaded to the California <br />Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit for <br />review by the EHD. <br />This is a repeat violation, Class Il. <br />109 <br />CCR 2637 Failed to test secondary containment. <br />Secondary containment testing was performed late. The previous test was conducted on 7-27-2011 and was due by <br />8-27-2014. The secondary containment testing was conducted on 11-06-13 (passing results for UDC -13, UDC 14-15, <br />and UDC -16 only were received), and on 8-19-14 for all remaining components with exception of UDC -13, UDC 14-15, <br />and UDC -16 (tested on 11-06-13). Secondary containment testing is required once every 36 months. The secondary <br />containment testing for UDC -13, UDC 14-15, and UDC -16 is is due by 11-16-2016 and for the rest of the components <br />by 7-27-17. Take all necessary precautions to ensure testing is performed in a timely manner. <br />This is a Class II violation. <br />123 <br />CCR 2661 Permit to repair UST system not obtained. <br />The concrete was broken in the vicinity of the "auto site" UDCs and fuel piping and a permit was not obtained from the <br />EHD. Emergency repairs relating to UST system monitoring and release detection may be performed by a properly <br />licensed, trained, and certified contractor pursuant to the EHUS policy and a permit obtained within one business day <br />from the EHD. All other repairs must have a permit submitted to and approved by the EHD prior to beginning work. <br />Immediately obtain a permit from the EHD for these repairs. An incomplete permit application was received on 5-6-16; <br />immediately submit the complete permit application to the EHD. A "Failure to Obtain a Permit" penalty applies. <br />This is a Class II violation. <br />204 <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. The monitoring plan uploaded into CERS <br />for the onsite oil water separator is not current and/or not approved by the EHD. The monitoring plan for the onsite oil <br />water separator indicates that the leak alarm triggers the automatic pump shut down and failure or disconnection of <br />the sensor also triggers an automatic pump shut down. A copy of these plans shall be accessible on site at all times. <br />Immediately make the necessary corrections and retain a copy on site. <br />This is a Class II violation. <br />Page 4 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.