Laserfiche WebLink
r <br /> leEmge <br /> SNORT FORM: 4.External Hydrostatic Pressure: Tank shall be capable <br /> of being buried in ground with 7'of overburden \ <br /> The contractor shall provide Double Wall Fiberglass over the top of the tanks, the hole fully flooded ll <br /> Reinforced Plastic (FRP) Underwriters Laboratories-labeled and a safety factor of 5:1 against general buckling. <br /> underground storage tanks as shown on the drawings. Sizes <br /> and fittings shall be as shown. The tanks shall be fiberglass 5.Tanks shall support accessory equipment-such <br /> tanks as manufactured by Xerxes Corporation. heating coils, drop tubes, submersible pumps and <br /> ladders-when installed according to tank manu- <br /> Tanks shall be tested and installed with pea gravel or crushed facturer's recommendations and limitations. <br /> stone as specified in the current installation instructions pro- <br /> vB. Product Storage: <br /> ided with the tank. <br /> I. Tanks shall be capable of storing petroleum prod- <br /> ucts with specific gravity up to 1.1. <br /> 2. Tanks shall be vented to atmospheric pressure. The <br /> LONG FORM: Section 13177-1 tank is not designed as a pressure vessel, except for <br /> use with vapor-recovery systems, provided the <br /> Part l: General pressure of vacuum does not exceed 1 psi. <br /> 1.0 Related Work Specified in Other Sections 3. Gasoline;gasohol (90%gasoline/10%ethanol mix <br /> A. Liquid-Level Gauges:Section 15174 tune; 90.5%gasoline and 9.5%Oxinol-50' (4.75% <br /> methanol and 4.75%GTBA mixture); Dupont EPA <br /> B. Plastic Pipe: Section 15064 waiver(gasoline with 5%methanol and a minimum <br /> C.Anchor Bolts:Section 05501 of 2.5%cosolvent-gasoline with up to 20% (by vol- <br /> D. Cast-in-Place Concrete: Section 03300 ume) of MTBE; gasoline/water/ethanol or methanol- <br /> blend motor fuels, including 100%ethanol or <br /> 1.02 Quality Assurance methanol or M85 (85%methanol)at ambient tem- <br /> A.Acceptable Manufacturer:Xerxes Corporation peratures:jet fuel; av-gas; kerosene; diesel fuel; new <br /> or used motor oil; or used for fuel oil at temperatures <br /> B. Governing Standards, as applicable: not to exceed 150° F. <br /> 1.ASTM standard document number D4021-86. C. Materials: <br /> 2. Underwriters Laboratories, Inc. (U.L)Standard for I.Tanks shall be manufactured with 100%resin and <br /> Safety 1316, File MH 9061 for storage of flamma- glass fiber reinforcement. No sand fillers. <br /> ble liquids.A U.L-certification plate shall be \ <br /> attached to each tank. D. Tank Dimensions (Refer to Xerxes literature on /) <br /> gallonage.): <br /> 3. National Fire Protection Association (NFPA) <br /> Standards: I.Tank shall have nominal capacity of gallons. <br /> NFPA 30: Flammable and Combustible Liquids 2.Tank shall have nominal outside diameter of_ <br /> Code <br /> feet. <br /> NFPA 30A:Automotive and Marine Service Station 3.Tanks shall have approximate overall length of <br /> Code feet. <br /> NFPA 31: Installation of Oil-Burning Equipment. E. Interstitial Space <br /> 4. Factory Mutual Systems approval IM7AOAF. 1.Tank shall have a space between the primary and <br /> secondary shelf walls to allow for the free flow and <br /> 5. City of New York Department of Buildings M.E A., containment of all leaked product from the primary <br /> Division#161-89-M tank. The space also allows the insertion of a moni- <br /> 6.Los Angeles Fire Department toring device through a monitoring fitting. <br /> Part ll' Products 2.02 Appurtenances and Accessories <br /> A. Optional Anchor Straps <br /> 2.01 Double Wall Fiberglass Reinforced Plastic (FRP) 1.Straps shall be FRP anchor straps as supplied by <br /> Underground Storage Tanks: <br /> tank manufacturer. <br /> A. Loading Conditions-Tank shall meet the following 2.Number and location of straps shall be specified in <br /> design criteria: current literature by tank manufacturer. <br /> 1.Internal Load: Tank shall withstand a 5 psi air <br /> pressure test with 5:1 safety factor. Contractor B. Manways <br /> shall individually test tanks for leakage prior to I.AII manways are to be flanged and 22"I.D., com- <br /> installation. Maximum test pressure is 5 psi. plete with U.L.listed gaskets, bolts and covers. (30- <br /> 2.Vacuum Test:To verify structural integrity, every and 36"1.D. manways are also available. <br /> tank shall be vacuum tested by the manufacturer at 2.Location is shown on standard tank drawings. <br /> the factory to 1 1.5 inches of mercury. 3.Optional manway extension tubes shall be FRP and <br /> 3.Surface Loads:Tank shall withstand surface H-20 24"long. <br /> axle loads when properly installed according to 4.Each steel manway cover shall have a minimum of <br /> manufacturer's current installation instructions. three 4"NPT fittings. (See Dimensional Data on <br /> page 7-9 for actual size and quantity of fittings.) <br /> 'TM Arco Chemical Co. <br /> 18 <br />