My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2003-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 1:15:55 PM
Creation date
6/23/2020 6:57:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2005
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2003-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
442
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page of <br /> 7. ER-DISPENSER CONTAINMENT(UP)TESTING <br /> Test Method Developed By: UDC Manufacturer ❑ Industry Standard ® Professional Engineer ❑ <br /> Other(Specify) <br /> Test Method Used: Pressure ❑ Vacuum ❑ Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution: .00007 <br /> Under-Dispenser Containment Number Below <br /> 11 -7 <br /> ID�Manufacturer: Gn t t3 -- <br /> UDC Material: P\166t�t�3 <br /> UDC Depth: ,5 .° <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: t1 UOPI Clem v <br /> Portion of UDC Tested' 2"Above Highest 2"Above Highest 2"Above Highest 2"Above Highest <br /> Penetration Penetration Penetration Penetration <br /> Does turbine shut down when ❑Yes❑ No NA® ❑Yes❑ No NA® ❑Yes❑ No NA® ❑Yes❑ No NA® <br /> UDC sensor detects liquid. <br /> Turbine shutdown response time ❑Yes❑ No NA® ❑Yes❑ No NA® ❑ Yes❑ No NA® ❑Yes❑ No NA® <br /> Is system programmed for fail- ❑ Yes❑ No NA® ❑Yes❑ No NA® 0 Yes❑ No NA® ❑Yes❑ No NA® <br /> safe shutdown?` <br /> Was fail-safe verified to be ❑Yes❑ No NA® ❑Yes❑ No NA® ❑Yes❑ No NA® ❑Yes❑ No NA® <br /> opera onal?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test G <br /> Test Start Time: -.Vo <br /> Initial Reading(Rt): 7 S1`7 3 2.5(,4 3 !.�j8� Z-1'1 <br /> Test End Time: , 05' 3, 01 1 02- °•'2� 2 2 0� <br /> Final Reading(RF): .'(111 ) .301 /•Y5 if 2,1� �.� �3 2. 0 0 ti <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(RF-RI): ,00o i 9 r o GG 19 ,00021 .0002-6 oW1,0002-1 <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 <br /> I- . 1 <br /> Was sensor removed for testing? Yes❑ No NAE] Yes❑ No NA❑ Yes❑ No NAE] ❑Yes❑ No NA❑ <br /> Was sensor properly replaced and ❑Yes❑ No NA❑ ❑Yes❑ No NAE] (i Yes❑ No NA❑ ❑Yes❑ No NA❑ <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing and recommended follow-up for failed tests) <br /> BP Arco # 6347 <br /> 2430 Joe Pombo Pkwy <br /> Tracy, Ca 95377 <br /> SB 989 Testing <br />
The URL can be used to link to this page
Your browser does not support the video tag.