My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1022
>
2200 - Hazardous Waste Program
>
PR0519099
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 3:34:55 PM
Creation date
6/30/2020 3:21:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0519099
PE
2229
FACILITY_ID
FA0014293
FACILITY_NAME
GILL EXPRESS INC
STREET_NUMBER
1022
Direction
E
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102004
CURRENT_STATUS
01
SITE_LOCATION
1022 E FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 . 0 INSPECTION OBSERVATIONS <br /> A detailed formal visual exterior inspection of the AST was performed in accordance with the <br /> STI STANDARD FOR THE INSPECTION OF ABOVEGROUND STORAGE TANKS , SP001 , 6" <br /> edition , issued January 2018 , and adhered to regulatory requirements specified in the California <br /> Code of Regulations ( CCR) , Title 22 , Division 4 . 5 , Chapter 15 , Article 10 , Sections 66265 . 191 to <br /> 66265 . 202 . ATTACHMENT A, STEEL TANK INSTITUTE FORMAL AST INSPECTION <br /> FORM , contains the inspection findings generated for AST- 1 . A summary of the exterior , visual <br /> inspection observations for AST- 1 follows : <br /> AST- 1 is a nominal 1 , 000-gallon , UL 142 listed ( No . 31335) , rectangular , single-wall , welded <br /> steel tank containing used oil . The AST is located in an enclosed steel structure that provides <br /> secondary containment of the AST. A 164ch high by 32-inch long access port with a hinged <br /> cover provides access to the east top of the AST where the AST appurtenances are located . <br /> The AST appurtenances consist of the following : <br /> • One 4- inch plugged port; <br /> • One 24ch poly normal vent; <br /> • One Franklin Fueling Systems 5w inch emergency vent , model number 803-200-01 ; <br /> • One 2- inch port equipped with a compressed air operated high- liquid level shut-off valve <br /> and audible alarm whistle . A product return flexible poly pipe is also connected to this <br /> port. A 0 . 5-inch flexible poly pipe is used to return overfill product to the used oil drain <br /> pan in the Maintenance Shop ; <br /> • One 2- inch port used as the discharge for the AST that is equipped with a quick connect <br /> cap and nipple ; <br /> • One 0 . 5- inch sampling port covered by a threaded cap ; <br /> • One 2- inch port equipped with a Scully Golden Gallon Gauge® direct readout product <br /> level gauge ; <br /> • One 0 . 75-inch fill port connected by a 0 . 75- inch poly pipe to the pneumatic pump ; and <br /> • Mounting brackets for a pneumatic pump ' . <br /> The secondary containment structure was observed to be free of external leaks and was steel <br /> plate thickness tested using an ultrasonic thickness gauge equipped with a dual element <br /> transducer 2 . The north , east, west , and base steel plates of the secondary containment <br /> structure were ultrasonic thickness tested . Access to the south side of the secondary <br /> containment structure was limited due to the Facility Maintenance Shop wall being directly <br /> adjacent to the south steel plate of the secondary containment structure . ATTACHEMENT B , <br /> UTRASONIC THICKNESS GAUGE READINGS contains information regarding the locations of <br /> the ultrasonic thickness gauge point readings and the thickness data of each point as recoded <br /> from the ultrasonic thickness gauge . <br /> Dave Dooley , Steel Products Manager, Containment Solutions , Inc . was contacted and has <br /> confirmed the AST and secondary containment structure were manufactured by Containment <br /> Solutions®, Inc. , 2600 Pegasus Drive , Bakersfield , CA 93308 . The serial number associated <br /> with this SafeWasteTM System , AST and secondary containment structure , is 772021 . The <br /> SafeWasteTM System was manufactured in May 2004 and delivered to G & S Truck and Tire , <br /> ' The pneumatic pump has been installed in an interior location of the Facility Maintenance Shop, <br /> 2 Olympus Ultrasonic Thickness Gauge, Model 45MG , Serial Number 130237710 , Olympus Dual Element 7 . 50 MHz transducer, <br /> Model Number D7908, Serial Number 1099854. <br /> Gill Express Page 2 December 2018 <br />