® Test Results.The QA/QC Consultant will examine all results from laboratory acceptance testing and <br /> will report any nonconformance to the Construction Manager. <br /> Acceptance Test Failure.If a Geocomposite acceptance sample does not comply with the minimum <br /> requirements of the Specifications,the Geocomposite roll from which the sample was taken will be <br /> failed by the QA/QC Consultant,and replaced by the Geocomposite Manufacturer at no additional <br /> cost to the Owner. The Design Engineer shall be contacted to determine additional acceptance <br /> testing requirements. <br /> 4.4.3 Geocomposite Drainage Net Installation <br /> Surface Preparation. Before geocomposite installation, the QA/QC Inspector will: <br /> • Verify that all lines and grades have been verified by the Earthwork Contractor. <br /> • Verify that the underlying geomembrane has been prepared in accordance with the <br /> specifications, and that all associated documentation has been completed. <br /> • Verify that soil or geomembrane surfaces do not contain protrusions that could damage <br /> the geocomposite. <br /> • Verify that there are no excessively soft areas that could damage the geocomposite. <br /> • All construction stakes have been removed. <br /> • Verify that all aspects of surface preparation have been performed according to the <br /> specifications. <br /> Geocomposite Placement and Seaming. During geocomposite placement the QA/QC Inspector <br /> will: <br /> • Observe the geocomposite as it is deployed and record all defects and defect corrective <br /> actions(panel rejected,patch installed,etc.). Verify that corrective actions are performed <br /> in accordance with the specifications. <br /> • Verify that equipment used does no damaged the geocomposite by handling,equipment <br /> transit, leakage of hydrocarbons, or other means. <br /> • Verify that crews working on the geocomposite do not smoke, wear shoes that could <br /> damage the geocomposite, or engage in activities that could damage the geocomposite. <br /> • Verify that the geonet side of the geocomposite is placed against the smooth side of the <br /> Page 41 <br />