Laserfiche WebLink
the 100-year/24-hour storm event, the design standard for the drainage <br />facilities established at closure. <br />5.9 VANDALISM <br />The following procedures will be followed during incidents of vandalism: <br />• Repair (i.e., replace, repaint) any portion of the property which has been <br />vandalized. <br />• Immediately repair any vandalism, which affects site security and/or <br />environmental control/monitoring systems. <br />• A review of the adequacy of site security after each incident shall be <br />performed. <br />t ' •LWZN�;IW <br />Underground landfill fires occur due to air intrusion and moisture into the refuse <br />cell. Indicators of underground fires are as follows: <br />• Unusual depression -like settlement with tension cracks. <br />• Smoke/steam. <br />• Unusual odor. <br />• Gas monitoring probe readings. <br />Should any of the above indicators be noted, the first course of action should be <br />placement of soil to cover the depression and/or cracks. If this measure does <br />not correct the problem, additional measures may be taken under the direction <br />of the SSO. <br />Contacts should be made with appropriate emergency response agency <br />representatives and the following information should be conveyed: <br />• Familiarize them with the layout of the facility, the properties of the waste <br />materials deposited, and the evacuation routes. <br />• Establish understandings between the responding Police/Sheriff and Fire <br />Departments and designate which agency has primary emergency authority <br />during an incident. <br />Forward Landfill FPCPCMP 5-5 <br />):\Allied\Forward\2005.0051 Partial Closure\Partial Closure Plan\FL•sec 5.doc: 6/9/2005 <br />