My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1993-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
3242
>
4400 - Solid Waste Program
>
PR0440068
>
COMPLIANCE INFO_1993-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2021 2:45:06 PM
Creation date
7/3/2020 11:10:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1993-2007
RECORD_ID
PR0440068
PE
4434
FACILITY_ID
FA0001871
FACILITY_NAME
CALIFORNIA CLAY LANDFILL
STREET_NUMBER
3242
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17702029
CURRENT_STATUS
02
SITE_LOCATION
3242 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440068_3242 S EL DORADO_1993-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
400
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
>'u VF <br />y. 9 <br />_ a <br />1gg8 <br />Mr. Victor Izzo Page 3 of 5 <br />RWQCB — Central Valley Region Clayton Project No. 80-03242.00.500 <br />May 31, 2006 <br />boundary and east of Universal Recycling Services. These wells will be installed in general <br />compliance with Clayton SOP -5 Monitoring Well Installation and SOP -6 Groundwater Well <br />Development and Surveying (attached). <br />Similar to the initial groundwater investigation, to collect the data needed to evaluate the <br />groundwater quality at the site and to properly scope any further investigation activities, Cove <br />Contractors proposes the following activities: <br />® Install replacement groundwater monitoring wells_ <br />• Purge and sample the groundwater monitoring wells <br />® Conduct further investigation <br />Further details regarding these activities are provided in the following paragraphs. All onsite <br />activities will be conducted under the site-specific Health and Safety Plan for the site. <br />Groundwater sampling will be conducted in accordance with Clayton SOP -7 Groundwater <br />Sampling and SOP -3 Decontamination of Field Equipment (attached). Other pertinent SOPS, <br />such as SOP -8 Acquisition and Interpretation of Water -Level Data and SOP -9 Field <br />Measurement of pH, Conductivity, and Temperature of Surface Water and Groundwater are also <br />attached. Two rounds of groundwater sampling are proposed to be conducted prior to scoping <br />additional investigation activities, which will include finalizing the locations for the MW -9 and <br />MW -10 replacement wells. Groundwater samples will be analyzed for: <br />• VOCs in accordance with USEPA Method 8260B, including Acrylonitrile, trans- l-4- <br />Dichloro-2-butene, and Iodomethane <br />® CAM 17 metals in accordance with USEPA Methods 6010B and 7471 <br />• Sulfate, Nitrate and Chloride in accordance with USEPA Method 300.0 <br />• Calcium, Magnesium, Potassium, Iron, and Sodium in accordance with USEPA <br />Method 7470A <br />• pH in accordance with USEPA Method 150.1 <br />• Total Dissolved Solids (TDS) in accordance with USEPA Method 160.1 <br />• Alkalinity (as CaCO3) and carbonate in accordance with SM Method 2320B <br />The purge water will be characterized based on the analytical results and it will be profiled and <br />disposed. <br />Based on the results of the groundwater sampling, additional groundwater monitoring wells may <br />be proposed. If additional wells are required, they will be installed in general compliance with <br />S:\ES\Proj\P03242\Groundwater\Workplan 2006\GW_installation and abandonment_WPL_FINAL.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.