COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2500
>
2300 - Underground Storage Tank Program
>
PR0232507
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2020 12:57:37 PM
Creation date
7/7/2020 1:48:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0232507
PE
2361
FACILITY_ID
FA0003846
FACILITY_NAME
Verizon Business: LDIKCA
STREET_NUMBER
2500
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
029-030-39
CURRENT_STATUS
01
SITE_LOCATION
2500 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PEI / RP1200 12 <br /> 6 . 2. 1 Purpose . This method is used to test the <br /> 6w SPILL BUCKET AND integrity of single - walled spill buckets or the pri - <br /> CONTAINMENT SUMP mart' containment of secondarily contained spill <br /> TESTING buckets . <br /> 6 . 2 . 2 Description of Test . The spill bucket is <br /> 6 . 1 General. Spill buckets and containment sumps for filled with water. The water level is rneasured at the <br /> tank systems are neither intended nor designed for the beginning and end of the test . <br /> storage of petroleum products , but rather to contain small 6 2 3 Test Equipment. Test equipment shall <br /> leaks and spills for short periods of time . This section include : <br /> describes the procedures used to test the integrity of spill <br /> buckets and containment sumps to ensure that they do not water ; <br /> Icak . Y measuring stick that is accurate to within 1 / 16 <br /> 6 . 2 Spill Bucket Integrity 'testing — Hydrostatic (0 . 063 ) inch and of sufficient length ; <br /> Test Method . plumber ' s plug ( appropriate size , if used ) ; <br /> stopwatch or other time-measurement device <br /> " fl fro not use fuels such as Baso- capable of measuring a 1 - second incrcment . <br /> line , E85 or diesel as a test fluid because <br /> they present a serious fire and safety 6 . 2 . 4 Preparation . <br /> hazard . Gasoline vapors are flammable 1 . Care should be taken when conducting the test <br /> and can explode if exposed to an ignition in the rain or during freezing weather condi - <br /> source such as a spark or open flame . If tions . <br /> a tank or containment area is not tight , <br /> using fuel as the test fluid will cause a 2 . Remove and properly dispose of any liquid and I <br /> release into the soil or groundwater. debris (leaves , sediment and trash ) in the spill <br /> bucket . Clean the spill bucket and examine it for <br /> damage , defects or improperly installed compo - <br /> nents. If these are loose components ( c . g . , loose <br /> band clamps or bolts) , tighten these items before <br /> conducting the integrity test . If there are items <br /> that must be repaired or replaced (e . g . , deterio - <br /> water Level _ rated gaskets/seals or drain valves ) , notify the <br /> owner/operator. <br /> 3 . Examine 8le fill cap and adapter fitting foil <br /> loose, missing or damaged parts , and make <br /> necessary repairs . Complete any repairs before <br /> putting water in the spill bucket . 'Make sure that <br /> the seat on the fill cap is present and in good <br /> condition . The cap must fit securely and be leak- <br /> tight on the riser. The water level during the test <br /> typically will be above the cap , so a leaking cap <br /> will result in a failed test . As an alternative to a <br /> tight fill cap , use a plumber ' s plug in the fill riser <br /> FIGURE 6-,1. The hydrostatic method of determining if approved by the authority having jurisdiction <br /> spill bucket integrity uses water to detect leaks. The ( AHJ ) and tank ownei . <br /> measuring stick must be placed in the same location <br /> at the beginning and end of the test period to ensure 4 . The spill -bucket drain valve, if present , must <br /> be leak- tight t <7 pass the test . ] f it is not leak <br /> accurate water level readings . <br /> tight , it may be possible to simply remove and <br /> permanently plug the drain valve, However, if <br /> you choose to permanently plug , ensure that the <br /> local regulations allow this modification , <br /> pei , org <br />