Hazardous Waste Contingency Plan <br /> alarm pull box is located on the southwest side of the building . A sprinkler system runs throughout <br /> the building . The locations of fire extinguishing equipment and the pull box are identified on Figure 2 . <br /> A spill kit and an eye wash station are located adjacent to the HHMA CSA and at several others <br /> areas throughout the building . Spill kits are equipped with an empty drum , absorbent material , trash <br /> bags , mild cleaner , a broom , dust pan , shovel , permanent marker , safety glasses and single- use <br /> nitrile gloves . The exact locations of the spill kits and eye wash stations are identified on Figure 2 . <br /> Site personnel use two-way radios or , if necessary , cell phones to communicate with each other <br /> during emergencies . <br /> Emergency response equipment will be inspected on a monthly basis . These inspections include the <br /> quantity and operational condition of response equipment . Table 4 contains a list of emergency <br /> equipment at the Site . <br /> The Emergency Coordinator, or designee , inspects the emergency response equipment . After <br /> completion , the inspector signs the inspection form . Completed inspection forms are maintained <br /> electronically for a minimum of 3 years . <br /> Table 4 . Emergency Equipment List <br /> • . escription I Capabilities� <br /> Spill Response HHMA CSA Absorbent materials to clean up liquid spills and leaks . <br /> Equipment ( Spill Kits ) Central Bay , and Trash bags to dispose of used absorbent materials <br /> North , South , and and PPE . <br /> East perimeter of Empty drums to dispose of waste generated at the <br /> building Site . <br /> Mild cleaner ( not for personnel hand washing ) to clean <br /> affected areas , as needed . <br /> • Broom , dust pan and shovel to pick up spilled material . <br /> • Permanent markers are used to fill out labels and <br /> immediately identify waste streams . <br /> Fire Extinguishers HHMA CSA and • Class ABC fire extinguishers are located at the HHMA <br /> throughout building CSA and throughout the building on the outside wall <br /> near most fire exits and interior support beams . <br /> Fire Alarm Pull Box Perimeter of building The fire alarm pull box provides a means to alert <br /> personnel of a fire or emergency . <br /> Sprinkler System Throughout building The wet sprinkler system provides fire suppression for <br /> the entire building- and is fed via the public water line . <br /> Emergency Management has Two-way radios and cell phones provide a means of <br /> 1 y Communication radios and cell communication during any emergency condition (such <br /> Equipment phones as fire , spills , etc . ) . <br /> • The PA system provides a means to communicate an <br /> J (two-way radios , cell Building PA system emergency to all Site personnel . <br /> phones , Public • Emergency contact information is located near the <br /> Address ( PA) system ) <br /> l HHMA CSA and aids in notification . <br /> � I <br /> II <br /> arcadis . com 10 <br />