Laserfiche WebLink
• Sparge air and helium flow rates and air pressure at the sparge test well <br /> by use of pneumatic in-lune flowmeter and pressure indicators every 15 <br /> minutes. <br /> • Sparge air temperature by use of an in-line air temperature gauge at the <br /> sparge well. <br /> • Hydrocarbon concentrations as measured by a volatile hydrocarbon meter <br /> in wells with exposed screened intervals above the water table before <br /> sparge, every hour during sparging and after sparge ng. <br /> • Helium concentrations in the saturated zone in sparge monitoring wells by <br /> use of a helium detector capable of detecting up to 100 parts per million <br /> of helium every 15 minutes. <br /> • Dissolved oxygen (DO) concentrations in the sparge monitoring wells and <br /> sparge well before and after spargmg at each flow rate using a field DO <br /> meter. <br /> Day Two <br /> 1. After completing the sparge tests, the preliminary data collected from the SVE <br /> test and the AS tests will be evaluated to deternune the optimum conditions for <br /> the combined AS/SVE test. Optimization will be based on estimated radius of <br /> influence data obtained from induced vacuum measurements during the short-term <br /> SVE tests performed by Brown and Caldwell and from water levels, DO, helium, <br /> and FID (or PID) readings during the sparge tests. The combined test will be <br /> performed on the test wells used for the AS and SVE tests. SVE will be initiated <br /> at a mmamum of two times the optimal sparge air flow rate before spargmg <br /> begins. No helium will be used during the combination test. <br /> 2. Initially, the SVE system will be operational until approximate steady-state <br /> conditions are achieved, followed by AS in combination with SVE for the <br /> remaining prod. The following parameters will be monitored: <br /> • Decrease in induced vacuum readings in sparge monitoring wells as a <br /> result of spargnng every 15 minutes. <br /> • Extraction air flow rates and applied vacuums at the SVE well every 15 <br /> minutes. <br /> Extracted vapor temperatures by an nn-line temperature gauge. <br /> • Sparge air flow rates, sparge temperature, and applied air pressures m the <br /> sparge well every 15 minutes. <br />