My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
420
>
2300 - Underground Storage Tank Program
>
PR0231906
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/8/2021 3:18:10 PM
Creation date
7/22/2020 4:14:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231906
PE
2361
FACILITY_ID
FA0003776
FACILITY_NAME
KWIK SERV LODI BW 113*
STREET_NUMBER
420
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06202042
CURRENT_STATUS
01
SITE_LOCATION
420 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
179
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: O Sump Manufacturer 0 Industry Standard X Professional Engineer <br /> 0 Other (Spec& <br /> Test Method Used. 0 Pressure 0 Vacuum X Hydrostatic <br /> 0 Other (Sped) <br /> 'fest Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .002 <br /> Sump # 147 Sump # 2-Race 100 Sump # 3-91 Sump # 4Diesel <br /> Sump Diameter: 42" 42" 42" 42" <br /> Sump Depth: 38 38" 39" 41 " <br /> Sump Material : Fiberglass Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of 15 16" 16" 15 " <br /> Highest Piping Penetration : <br /> Height from Tank Top to Lowest 9„ <br /> Electrical Penetration: <br /> Condition of sump prior to testing. Dry Dry Dry Dry <br /> Portion of Sump Tested' Water Level 19" Water Level 20" Water Level 20" Water Level 19" <br /> Does turbine shut down when <br /> sump sensor detects liquid (both Yes Yes Yes Yes <br /> product and water)?* <br /> Turbine shutdown response time Not Alarmed Not Alarmed Not Alarmed Not Alarmed <br /> Is system programmed for fail-safe Yes Yes Yes Yes <br /> shutdown?` <br /> Was fail-safe veri-fied to be No No No No <br /> operational?* <br /> Wait time between applying water 5 Minutes 5 Minutes 5 Minutes 5 Minutes <br /> and starting test: <br /> Test Start Time : 9 : 32 8 :47 9 :42 8 :42 <br /> Initial Reading (Rr) : . 001 .001 .001 600I <br /> Test End Time : 10 : 02 9: 17 10 : 12 9 : 12 <br /> Final Reading (Rr.) . . 001 . 001 .001 .001 <br /> Test Duration: 30 Minutes 30 Minutes 30 Minutes 30 Minutes <br /> Change in Reading (Rr. Rr) : 0 0 0 0 <br /> Pass/Fail Threshold or Criteria: . 005/30 Minutes .005/30 Minutes .005/30 Minutes .005/30 Minutes <br /> Test Result: Pass Pass Pass Pass <br /> Was sensor removed for testing? Yes Yes Yes Yes <br /> Was sensor properly replaced and <br /> verified functional after testing? Yes Yes Yes Yes <br /> j� <br /> Comments — (include information on repairs made prior to testing, and recommended follow-zip for failed tests) I <br /> If the entire depth of the sump is not tested, specify how much was tested. If the answer to ay of the questions indicated with an <br /> asterisk M is "NO" or "NA", the entire sump must be tested. (See SWRCB LG - 160) <br />
The URL can be used to link to this page