My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0232437
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 10:38:59 AM
Creation date
8/3/2020 11:39:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0232437
PE
2361
FACILITY_ID
FA0003787
FACILITY_NAME
SHERIFFS OPERATIONS CTR #1
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.s'gov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: I Date: <br /> SHERIFFS OPERATIONS CTR#1 7000 N MICHAEL CANLIS RD, FRENCH CAMP January 25, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> A designated operator inspection was performed on December 18, 2018 and the next inspection was performed on <br /> January 22, 2019, 34 days later. The designated operator visual inspections shall be conducted within 30 days or <br /> less of the previous inspection. Ensure that all designated operator inspections are performed within the required <br /> time frames. <br /> The designated operator failed to check and note all required items on the visual inspection reports. <br /> -The February 2018 inspection report included incorrect monitoring system certification and spill bucket test dates <br /> (1/23/17). The correct date was 1/26/18. <br /> -The 10/29/18 inspection report left blank the question regarding UDC sensor locations. <br /> -The 12/18/18 inspection report did not include the date signed by the owner/operator. <br /> -The 1/22/19 inspection report was not signed by the owner/operator. <br /> During the visual inspection, the designated operator shall check that all required testing and maintenance for the <br /> UST system have been completed and shall check all required items on the report. Ensure that designated <br /> operators performing visual inspections at this facility are including all of the required information on the reports. <br /> The designated operator failed to document all the alarms from the attached alarm history on the designated <br /> operator monthly inspection reports and failed to check that they were responded to appropriately. The missing <br /> alarms include: <br /> L1 (87 annular) sensor out alarms on 8/28/18 <br /> L5 (diesel UDC) sensor out alarms on 3/25/18, 4/13/18, 4/14/18, 4/25/18, 7/29/18, 8/2/18 <br /> During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months (after October 1, 2018). <br /> The June and July 2018 designated operator monthly inspection reports on site were not for this facility. <br /> Designated operator monthly inspection reports for the previous twelve months shall be retained on site. Locate <br /> and ensure that copies of the previous twelve months of designated operator monthly inspection reports are <br /> maintained on site. Submit copies of the missing reports to the EHD. <br /> This is a minor violation. <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> A fuel leak was observed under the diesel dispenser whenever the pump was running. All primary containment for <br /> the UST system must be tight. Immediately have a properly licensed, trained, and certified contractor repair or <br /> replace the failed component under permit and inspection of the EHD. <br /> This is a minor violation. <br /> FA0003787 PR0232437 SCO01 01/25/2019 <br /> EHD 23-01 Rev.09/22/16 Page 6 of 8 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.