Laserfiche WebLink
SAN'J O A Q U I NEnvironmental Health Department <br /> COUNTY— <br /> Underground <br /> �Izr�+� <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TRACY76 2420 W GRANT LINE RD, Tracy May 22, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months (after October 1, 2018). <br /> On the 10/5/18, 11/2/18, 12/11/18, and 2/4/19 designated operator(DO) inspection report under <br /> -Section I <br /> The DO failed to write the CERS ID <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A from section VII through XI. <br /> -Section VI <br /> The OWNER/OPERATOR failed to provide at least one of the following: name, signature, and date within 48 hours <br /> of receiving the DO report under the ACKNOWLEDGMENT OF COMPLIANCE ISSUES section. <br /> On the 1/2/19, 3/7/19 and 4/2/19 designated operator(DO) inspection report under <br /> -Section I <br /> The DO failed to write the CERS ID <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A from section VII through XI. <br /> -Section V <br /> The owner/operator failed to provide explanation of follow-up actions that will be taken for the statement provided by <br /> the DO in section III. <br /> -Section VI <br /> The OWNER/OPERATOR failed to provide at least one of the following: name, signature, and date within 48 hours <br /> of receiving the DO report under the ACKNOWLEDGMENT OF COMPLIANCE ISSUES section. <br /> On the 5/6/19 DO report: <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A or N from section VII through XI. <br /> -Section V <br /> The owner/operator failed to provide explanation of follow-up actions that will be taken for the statement provided by <br /> the DO in section III. <br /> -Section VI <br /> The OWNER/OPERATOR failed to provide at least one of the following: a name, signature, and date within 48 <br /> hours of receiving the DO report under the ACKNOWLEDGMENT OF COMPLIANCE ISSUES section. <br /> Furthermore the DO did not conduct an inspection with 30 days of the previous inspection. The DO inspected the <br /> facility on 11/2/18 and on 12/11/18. The DO report was conducted 39 days after the 11/09/18 inspection. The DO <br /> inspected the facility on 4/2/19 and on 5/6/19. The DO report was conducted 34 days after the 4/2/19 inspection and <br /> not within 30 days as stated by regulation. <br /> During the designated operator inspection, the designated operator shall review the alarm history for the previous <br /> month, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br /> history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br /> performing inspections at least once every 30 days at this facility and are including all of the required information on <br /> the reports. <br /> This is a repeat violation, Class II. <br /> FA0003963 PR0231580 SCO01 05/22/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 6 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />