REVISIONS <br /> 2"SCW OUTLET NO. DESCRIPTION DATE <br /> "__--'TO BFP-6 <br /> HB <br /> 7 <br /> BALL VALVE(TYPICAL) <br /> 2" <br /> FLOW <br /> (E)SHUT-OFF VALVE I - <br /> I N <br /> (TYPICAL)0 �" <br /> (E)2"CW FLUID COOLER <br /> TO STORE (E)1 1/2"CW HEADERS FLOW 1"TEE WITH ON ROOF <br /> LOW ON WALL O <br /> ZIP BALL VALVE BFP <br /> (E)HOSE BIB lD . I I . (TYPICAL) LINE SIZE ANTI-SIPHON 3 <br /> (E)UNION(TYPICAL)Ol - - - - - - I VACUUM BREAKER 3/4"CW- - - �� TO CLEANING SYSTEM <br /> 2"CW INLET FROM REDUCED PRESSURE n �n/l WITH SHUT-OFF VALVE RE:P2 -3/4"CW <br /> BACKFLOW PREVENTER SERVING WATER i i i B (TYPICAL) RE:P2 3/4"RO 3/4" 3/4" <br /> SOFTENER(BFP-5). RE:P2 n <br /> i E)-Q r&Q BFp 3/4"CW X3/4" I TO STEAMER <br /> n I <br /> n n 3n <br /> PLUMBING CONTRACTOR TO PROVIDE AND <br /> l@(E)2 CW `\ Icy INSTALL 2"WIDE,24 GAUGE G.I. SEISMIC - L- - 4 <br /> T ANCHOR.LOCATE WITHIN THE UPPER AND i i i ABOVE ROOF EVERPURE EV 9272-41 EVE URE EV 3111-61 <br /> QC7I SINGLE HEAD NEEDLE BLENDING <br /> /� / LOWER ONE OF ITS VERTICAL DIMENSION. Ca BELOW ROOF VALVE <br /> lO(E)2"CW UP FROM THE LOWER STRIP LOCATED TO MAINTAIN A SCW CD— SCW <br /> U <br /> BELOW GRADE i i FLOOR EVERPURE EV 9618-11 EVERPURE EV 9627-00 <br /> MINIMUM DISTANCE OF 4 INCHES ABOVE THE Q 7CB5 CARBON FII TER NE-CC ASSEMBLY ARCH.PROJECT NO. <br /> CONTROLS. BOLT TO STRUCTURE,SECURE TO U CARTRIDGE (SEE NOTE 2) 2004 <br /> NOTES: FRAMING WITH MIN. 1/4"x3"LG.LAG SCREWS. <br /> 1.RETAIN AND PROTECT. <br /> 1. COORDINATE NUMBER OF TEES REQUIRED AND EXACT WD <br /> 2.SHUT-OFF EXISTING DOMESTIC WATER SUPPLY AT (TYPICAL).RE:53.3-17. LOCATION FOR HEADER PIPING WITH SCW TANK VENDOR. FULL SIZE SCW FROM NOTES:_ DRAWN <br /> EXISTING MAIN SHUT-OFF VALVE AND REMOVE 2. VALVE BYPASS MANIFOLD,CHECK VALVE,2"COLD WATER AND REDUCED PRESSURE 1.ALL PIPING,FILTERS AND VALVES PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR. imc <br /> EXISTING DOMESTIC WATER PUMP AND ALL 2"SCW HEADER PIPING WITH 1"TEES AND BALL VALVES BACKFLOW PREVENTER ROUTE FULL SIZE TYPE L' 2.INCLUDES BW HEAD AND 7CC-BW CALCITE FEEDER CARTRIDGE. <br /> ASSOCIATED PIPING. PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR. COPPER DRAIN LINE INDIRECT 3.MOUNT BACKFLOW PREVENTERS NEXT TO COMBI-OVEN IN AN ACCESSIBLE LOCATION. CHECKED <br /> BELIMO B350L L-PORTED TO RECEPTOR WITH AIR GAP 4.CENTERLINE OF WATER SUPPLY TO BACKFLOW PREVENTERS SHALL NOT <br /> BALL VALVE(SIZE 2") EXCEED 60 INCHES HEIGHT ABOVE FINISHED FLOOR. RWD <br /> 3. PLUMBING MUST BE SECURED TO WALL WITH UNISTRUT COLD WEATHER <br /> AND CLAMPS PROVIDED AND INSTALLED BY PLUMBING WITH BELIMO AFRBUP 24V DRAIN PIPING 5.MINIMUM HEIGHT OF RELIEF PORTS TO FINISHED FLOOR SHALL BE 12 INCHES MINIMUM, SUBMITTAL DATES <br /> CONTRACTOR. VALVE ACTUATOR 30 INCHES MAXIMUM. <br /> 6.BACKFLOW PREVENTERS MAY BE STAGGERED ABOVE ONE ANOTHER PROVIDING 06/11/20 <br /> THEY MEET THE REQUIREMENTS OF NOTES 3 THRU 5,THIS DETAIL,AND LOCAL CODE. <br /> DOMESTIC BOOSTER PUMP <br /> DEMOLTION DETAIL WATER SOFTENER DETAIL FLUID COOLER PIPING DETAIL 4 COMBI OVEN DETAIL OTB DATE <br /> NTS <br /> NTS NTS NTS <br /> U w0 a <br /> z <br /> Oa ��Oyo: <br /> a O F U O <br /> U P. W � p�., o <br /> zxa �Az Z <br /> u w xz �Z W 96 <br /> E <br /> f� W c <br /> OaW A za Zo <br /> a w a V A t N <br /> REFRIGERATION DISPLAY CASE REFRIGERATION DISPLAY CASE > A z o I Z2 <br /> 3 N <br /> CASE CONDENSATE DRAIN WATER SUPPLY PIPING z Q o ' W � 3 0 <br /> LINE BY REFRIGERATION TO FREQUENTLY USED o w H H L) o <br /> CONTRACTOR FIXTURE CLEANOUT MAY EXTEND AS A H¢ w a G L <br /> WASTE OR VENT <br /> KICK PLATEz <br /> co <br /> STRUCTURE CONNECTORS STRUCTURE CONNECTORS FLOOR SINK HALF EXPOSED W u�0 �°oou <br /> (VERIFY WITH STRUCTURAL CONDITIONS) (VERIFY WITH STRUCTURAL CONDITIONS) IN FRONT OF KICK PLATE <br /> TP-1,TRAP SEAL PRIMER-/ FLOOR WALL <br /> ROUND,FLAT CHROME PLATED <br /> MIN. 1"HIGH STAINLESS STEEL n <br /> AROUND BACK HALF OF FLOOR FINISH FLOOR �1/2" BRASS OR STAINLESS STEEL <br /> COVER PLATE WITH SCREW <br /> STRUT PIPE CLAMP SINK UNDER CASE.SECURE M - <br /> iii O <br /> (TYPICAL) 1/2"THREADED ROD TO RIM OF FLOOR SINK W/ TO SEWER PLUGGED TEE W/CLEANOUT <br /> 1/2"THREADED ROD SILICONE CAULKING 2"TAILPIECE NOT TO EXCEED 24"IN LENGTH �2"PVC PIPE SLEEVE <br /> (TYPICAL) REQUIRED FOR COPPER <br /> REQUIRED FOR FIXTURES ON COMBINATION PIPE. (RE SLEEVE REQUIRED <br /> P FLOOR LINE0 LLI <br /> SINGLE WASHER BRWASTE AND VENT SYSTEM ONLY. FOR POLYBUTYLENE PIPE) C7 <br /> &NUT AT TOP 3"BRANCH LINE 3 3"x2"NO-HUB REDUCER AT TOP OF P-TRAP <br /> P-TR" AO u <br /> (TYPICAL) <br /> = a <br /> x o <br /> II II � Q U <br /> I I I I LL- <br /> SINGLE WASHER NOTE: RE:P5-21 -CASE FLOOR SINK GRATE DETAIL FLOOR DRAIN y W <br /> &DOUBLE NUT AT <br /> BOTTOM(TYPICAL) NOTE: • w Z <br /> IT IS THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR W <br /> co <br /> 15/8"UNISTRUT TO COORDINATE DRAIN LOCATIONS WITH THE REFRIGERATION 1 <br /> TRAPEZE CLEVIS HANGER CONTRACTOR AND REFRIGERATION PLANS TO ENSURE THE <br /> HANGER FLOOR SINKS ARE HALF EXPOSED WHEN THE CASES ARE INSTALLED. z W Q Q <br /> IF CONFLICTS EXIST,CONTACT THE ARCHITECT FOR A RESOLUTION L U7 <br /> BEFORE PROCEEDING. W <br /> _ a cc <br /> CASE FLOOR SINK DETAIL P-TRAP WITH PRIMER DETAIL WALL CLEANOUT DETAIL JL o <br /> 7 TYP. PIPE HANGER DETAIL g NTS 9 NTS to NTS N L <br /> NTS a � O <br /> z <br /> FESS <br /> H. <br /> � m <br /> 5 <br /> P: 12/31/21 <br /> �Tq F C C <br /> 06/11/20 <br /> FROM <br /> GAS <br /> SUPPLY <br /> GAS SHUT-OFFMANUAL SHUT-OFF VALVE WITH <br /> VALVE AN 1/8"N.P.T.PLUGGED TAPPING <br /> ACCESSIBLE FOR TEST GAGE O <br /> CONNECTION TO BE INSTALLED <br /> UPSTREAM OF THE GAS SUPPLY <br /> CONNECTION TO THE APPLIANCE. <br /> REMOVABLE CAP <br /> FULL SIZE OF GROUND JOINT <br /> TYPE'M'COPPERDRAIN CONNECTION UNION ~ <br /> UNION <br /> W � � <br /> DRAIN <br /> PAN <br /> TYPE'M'COPPER <br /> 1 � � <br /> ROUTE AT 1/8"/FT.SLOPE Q� <br /> MINIMUM. FLEXIBLE STEEL <br /> EQUAL TO FAN CONNECTION TO Q� <br /> NEGATIVE STATIC 6"TRAP(DRIP LEG) <br /> PRESSURE EQUIPMENT/ n ( ) <br /> ------' <br /> CONTROLS <br /> \ 1 MOUNT ON ROOF PER <br /> EQUAL TO 1/2 O <br /> Q _ DETAIL P547 AND <br /> FAN NEGATIVE INDIRECT TO EXISTING <br /> PRESSURE ROOF DRAIN. O O <br /> O <br /> O <br /> O O <br /> CONDENSATE DRAIN DETAIL I s GAS CONNECTION DETAIL <br /> NTS NTS <br /> MIRO MODEL 3-R-2 <br /> OR APPROVED EQUAL <br /> PIPE <br /> MIRO SPACER <br /> AS REQUIRED <br /> ROOF <br /> 7 3/4" <br /> REFRIGERATION LINE 4 3/4" <br /> 3" <br /> WATER LINE SECURE REFRIGERATED REMOVE <br /> 7 3/4" WATER LINE TO CASE CASE <br /> 4.. o MIDDLE <br /> 0 0 <br /> SEGMENT <br /> 0 <br /> 21/4" 0 SHEET TITLE <br /> 0 <br /> 01 <br /> NOTES: o CUT LINE <br /> 1.ROD AND PIPES SUPPORTED ONE PIPESTAND HIGH WILL HAVE A CLEARANCE E o <br /> OF 2.15". EACH 3-R SPACER INCREASES THE CLEARANCE OF THE PIPE BY 2". <br /> CUT LINE PLUMBING <br /> 2.MAXIMUM LOAD WEIGHT MAY NOT EXCEED 79 LBS.PER PIPESTAND. <br /> NOTES: <br /> 3.RECOMMENDED SPACING IS NOT TO EXCEED 7 FEET CENTERS DEPENDING ON 1. DIMENSION SHOWN IS FROM OUTSIDE OF GRATE. DETAILS <br /> THE LOAD. MAKE CERTAIN EACH PIPESTAND IS PROPERLY ELEVATED TO 2.GRATES TO BE CUT SHALL BE AT REFRIGERATED <br /> EVEN LOAD WEIGHT AT ALL PIPESTANDS. CASE FLOOR SINKS ONLY. <br /> CASE FLOOR SINK SHEET <br /> M ROOF MOUNTED PIPING DETAIL PRODUCE CASE PIPING DETAIL GRATE DETAIL <br /> 0 <br /> 0 17 NTS IO NTS 17 NTS P5 <br /> o� <br />