My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2021 4:48:00 PM
Creation date
2/22/2021 2:00:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
763
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
replace oil (or schedule oil maintenance from ARID Certified Permeator Technician) <br /> if oil change is warranted. The maintenance interval for draining and replacing the <br /> oil is every 5,000 hours (or once a year). If the oil level is low prior to the oil change <br /> interval, the owner/operator can `top up' the oil level (See ARID Permeator AT-150 <br /> section of IOM for Procedure). Only ARID Part Number AT-11 oil is authorized for <br /> usage in the Permeator AT-150. <br /> 1.3. Annual Inspection and Testing to Be Performed By a Certified Technician. <br /> The following procedures are recommended to be conducted in the order listed. <br /> 1 .3.1. Perform weekly and quarterly inspection prior to Annual Inspection. <br /> 1 .3.2. For GDF installations with CAS installed, conduct static pressure performance of <br /> the Healy Clean Air Separator (EO VR-201 or VR-202, Exhibit 4). <br /> 1 .3.3. Conduct pressure decay test (TP-201.3 and EO VR-201 or VR-202, Exhibit 8). <br /> 1 .3.4. For GDF installations with ARID Permeator AT-150 installed, conduct Permeator <br /> compliance procedure (EO VR-201 or VR-202, Exhibit 15). <br /> 1 .3.5. Conduct dispenser vapor line integrity test (Section B-3 of the Start-up / New <br /> Installation /Warranty / Annual Testing Form) found in the Healy dispenser manual <br /> for each dispenser at GDF. Repair all leaks. <br /> 1 .3.6. Conduct V/L test on all nozzles (EO VR-201 or VR-202, Exhibit 5 or a <br /> CARB approved alternate test procedure). Adjust and replace as <br /> necessary. <br /> 1.4. Procedure for Operator Reconnection of Breakaway and Testing Fueling Point after Drive- <br /> Off. <br /> Note: The following reconnection procedure does not require a Certified Technician <br /> as long as the components pass inspections and tests. If any of the tests fail, <br /> requiring removal of the fueling point or dispenser from service, contact a <br /> Certified Technician for repairs. Breakaway reconnections and/or service by <br /> the GDF owner/operator or a Certified Technician shall be entered into the <br /> GDF Maintenance Log. <br /> 1 .4.1. Inspection: <br /> After a Drive-Off, remove the dispenser from service and inspect the nozzle, hoses <br /> and breakaway for damage. If any of the components are damaged, replace them as <br /> necessary or contact a certified technician for repair. If the break-away has <br /> separated, proceed to the next section. <br /> Note: For Healy breakaways only, verify that the tip of the shear screw installed <br /> prior to the Drive-Off is removed from the dispenser end body (inlet) of the <br /> breakaway. If the tip cannot be removed, the breakaway must be replaced. <br /> 1-3 <br /> CARB Approved IOM 1 —Systems Scheduled Maintenance—EO's VR-201 and VR-202 <br />