Laserfiche WebLink
p. Connect the down spout tube to the Healy ball s. Install the conduit mounting plate to the lower <br /> valve assy. by screwing the nut on the tube to air gap plate & install a conduit washer over <br /> the fitting on the ball valve and tightening. See the conduit coming thru the lower air gap plate <br /> Picture 021. from the Healy subassembly. Secure plate <br /> with 2 screws. See Picture 024. <br /> 1 <br /> Picture 021 4 <br /> Picture 024 <br /> q. Reinstall the auxiliary junction box to the Healy <br /> sub assembly. Secure the box to the mounting t. Reinstall the upper conduit knockout plate to <br /> bracket by installing a nut to the stud coming the cd module using (2) screws. See Picture <br /> out of the back of the box. See Picture 022. 025. <br /> Picture 022 Picture 025 <br /> r. Feed the wires from the conduit & union u. Install a washer over the conduit and <br /> assembly thru the opening in the box and reconnect any cables that you disconnected. <br /> reinstall the union to the box. See Picture 023. See Picture 026. <br /> Picture 023 Picture 026 <br /> 8-27 <br /> CARR Approved IN 8-Gilbarco Encore 3OO E 5OO Series-Executive Orders VR-201 and VR-202 <br />