Laserfiche WebLink
Smith Environmental <br />SITE SAFETY PLAN <br />On-site communications: ❑ Radio 0 Verbal ❑ Hand Signals <br />❑ Other <br />Designate hand signals here: <br />Off-site communications: ❑ Radio ff] Telephone <br />❑ Other <br />The specific signal for an emergency is: Verbally Given <br />The specific signal for an evacuation is: Verbally Given <br />Evacuation assembly point is: To be determined on-site prior to beginning work activities. <br />MARK EVACUATION ROUTE(S) ON SITE MAP L7 CHECK WHEN DONE <br />SANITATION AND DECONTAMINATION <br />Personnel Decontamination Procedure: All contaminated personal protective equipment <br />(i.e., gloves, coveralls) will be placed on and <br />covered with 6 -mil plastic sheeting along with the <br />drill cuttings. <br />Location of Wash Water., Smith Environmental truck <br />Location of Toilet. Restroom at nearby truck stop <br />Location of Drinking Water: Smith Environmental truck <br />MARK LOCATION OF EYEWASH AND SHOWER DRENCH ON SITE MAP O CHECK WHEN <br />DONE <br />Equipment Decontamination Procedure: Equipment will be washed with a trisodium <br />phosphate solution and/or steamcleaned. <br />Materials to be Disposed of as Hazardous Waste: All soil and water produced will be stored <br />on-site until appropriate disposal methods <br />are determined. <br />PAGE 10 <br />