Laserfiche WebLink
j. MITIGATION MONITORING AND REPORTING PROGRAM: The project shall comply with all <br />required mitigations included in the MMRP dated August 8, 2022 <br />k. BUILDING CODE REQUIREMENTS: The following California Bung Code (CBC) and San Joaquin <br />County Ordinance requirements will be applicable to the proposed project. The following conditions <br />shall be addressed prior to submittal of a building permit application to the Building Inspection Division: <br />1. A building permit for each separate structure or building is required. Submit plans, Specifications <br />and supporting calculations, prepared by a Registered Design Professional (architect or engineer) <br />for each structure or building, showing compliance with The 2019 California Building, Existing <br />Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes as may be applicable. Plans <br />for the different buildings or structures may be combined into a single set of construction <br />documents. <br />2. A grading permit will be required for this project. Submit plans and grading calculations, including <br />a statement of the estimated quantities of excavation and fill, prepared by a Registered Design <br />Professional. The grading plan shall show the existing grade and finished grade in contour <br />intervals of sufficient clarity to indicate the nature and extent of the work and show in detail that it <br />complies with the requirements of the code. The plans shall show the existing grade on adjoining <br />properties in sufficient detail to identify how grade changes will conform to the requirements of the <br />code. <br />3. The required plans must be complete at the time of submittal for a building permit. Plans must <br />address building design and construction, fire and life safety requirements, accessibility and show <br />compliance with the current California codes and San Joaquin County ordinances. A complete set <br />of plans must include fire sprinkler plans, truss design submittals, metal building shop drawings, <br />structural plans and calculations, plumbing, electrical and mechanical drawings and energy report. <br />4. A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § 1 <br />104 for <br />grading. All recommendations of the Soils Report shall be incorporated into the construction <br />drawings. <br />5. For each proposed new building, provide the following information on the plans: <br />A. Description of proposed use <br />B. Existing and proposed occupancy Groups <br />C. Type of construction <br />D. Sprinklers (Yes or No) <br />E. Number of stories <br />F. Building height <br />G. Allowable floor area <br />H. Proposed floor area <br />I. Occupant load based on the CBC <br />J. Occupant load based on the CPC <br />6. Accessible routes shall be provided per CBC § 11 B-206. At least one accessible route shall be <br />provided within the site from accessible parking spaces and accessible passenger loading zones; <br />public streets and sidewalks; and public transportation stops to the accessible building or facility <br />entrance they serve. Where more than one route is provided, all routes must be accessible. §1113- <br />206.2.1 <br />7. At least 1 accessible route shall connect accessible buildings, accessible facilities, accessible <br />elements and accessible spaces that are on the same site. §11 B-206.2.2 <br />PA -2100077 —Conditions of Approval 3 <br />