Laserfiche WebLink
4" FILL ADAPTER AND CAP IN SPILL 37 38 <br />CONTAINMENT FILL BOX (TYP.) <br />FIBRELITE. MULTI -PORT DUAL POINT FIL 28 <br />SPILL CONTAINMENT ASSEMBLY W/ (2) 5 <br />GALLON SPILL BUCKETS CARB STAGE I EV 10 <br />COMPLIANT PER VR -102, <br />WATERTIGHT SUMP SHIELD 28 18° <br />BOOT AND CLAMPS <br />MINI HYDROSTATIC 212 I <br />SENSOR IN BRINE <br />FACTORY SUPPLIED °. p <br />RESERVOIR <br />. p <br />PEA GRAVEL BACKFILL (TYP.) <br />2 -IN -1 SENSOR BOX 217 <br />JUNCTION BOX 188 <br />SEE STATIC GROUNDING DETAILS - <br />ON SHEET G.0.7.2 (TYP.) <br />#4 STRANDED BARE CU <br />GROUND WIRE TO OTHER <br />TANKS (TYP.) <br />#4 STRANDED BARE CU <br />GROUND WIRE TO <br />GROUND ROD (TYP.) <br />1" FRP BONDED ENTRY FITTING 8 124 <br />(TYP.) <br />1" MONITORING CONDUIT <br />(ROUTED TO INTERSTITIAL) 5 187 <br />(ROBROY THROUGH SUMP ONLY) <br />42" DOUBLE WALL POLYGON SUMP <br />BODY (8) FLAT PANELS <br />SUMP MONITOR LIQUID SENSOR <br />MOUNTED IN HOLDER <br />39 40 4" VAPOR RECOVERY ADAPTER & CAP IN SPILL <br />CONTAINMENT FILL BOX. PER CARB EVR VR -102, <br />4" MIN. TO NO DRAIN VALVE (TYP.) <br />TOP OF SPILL <br />BUCKET 5 GALLON SPILL CONTAINER. <br />3'-87° NO DRAIN VALVE (TYP.) <br />8 <br />1 2 O3 O4 14 THICKENED <br />)CONCRETE <br />° 17 <br />a <br />id (TAPE z <br />° DEPTH 6" g <br />a . MIN. 12" t Ln <br />© MAX.) <br />4 6" WIDE DETECTABLE UNDERGROUND <br />° MARKING TAPE <br />EMPIRE MAGNATEC #32-143 <br />I 22 4" GALV. STEEL RISERS STAGE I VAPOR <br />RISER IS IN SAME PLANE AS TANK LEVEL <br />9 GAUGE IN THIS VIEW <br />4 <br />H12 <br />.5.3.15 i <br />19 EXTRACTOR FITTING <br />4"x4"x3%2" <br />OVERFILL PROTECTION (RO) 41 16 <br />TUBE SET AT 95% TYP. <br />A: SECTION VIEW - FILL SIDE SUM <br />SCALE: 3/4" = 1'-0" <br />SUMP MONITOR LIQUID SENSOR, <br />MANWAY JACK SCREW (TYP.) MOUNTED IN HOLDER1 8" <br />3" D.W. FRP BONDED ENTRY FITTING & 12612 eyi4 <br />4%3" CONCENTRIC REDUCER W/ TEST cn ! <br />PORT & VACUUM TUBING ROUTED TO �! <br />VAC SENSOR �j <br />2" INSIDE 3" DW F.G. VACUUM <br />MONITORED VENT LINE <br />11 14 148 I <br />i <br />I <br />2" BELL X MALE ADAPTER (TYP.) 14 <br />2"X18" FLEX CONNECTOR 15 174 <br />8 <br />H <br />1.3.1 <br />1/4" DRAIN/TEST <br />BUSHING. FACTORY <br />INSTALLED TO TEST <br />CONTINUITY <br />8" ACCESS PORT <br />3" OVER 2" FIBERGLASS <br />CROSSOVER CONTAINS VACUUM <br />TUBING ONLY TO VAC SENSOR <br />ASSEMBLY <br />3" D.W. FRP BONDED ENTRY FITTING <br />& 4"x3" CONCENTRIC REDUCER W/ <br />TEST PORT & PLUG <br />14 148 3" OVER 2" FIBERGLASS CROSSOVER <br />CONTAINS VACUUM TUBING ONLY TO <br />VAC SENSOR ASSEMBLY <br />j o 3" D.W. FRP BONDED ENTRY FITTING <br />12 126 <br />00& 4x3 CONCENTRIC REDUCER W/ <br />TEST PORT & PLUG <br />16 2" CAP. DRILL HOLES IN END AND <br />INSTALL GROMMETS FOR TUBING <br />PASS THROUGH <br />---- " <br />LOCATED AT 20K OR 30K TANK. <br />QB.PLAN VIEW - FILL SIDE SUMP (SINGLE FILL W/O MANWAY) <br />SCALE: 3/4" = 1'-0" <br />FIBRELITE. MULTI -PORT DUAL POINT FILL 28 <br />SPILL CONTAINMENT ASSEMBLY W/ (2) 5 <br />GALLON SPILL BUCKETS CARB STAGE I EVR10 <br />COMPLIANT PER VR -102, <br />4" FILL ADAPTER AND CAP IN SPILL 37 38 <br />CONTAINMENT FILL BOX (TYP.) <br />WATERTIGHT SUMP SHIELD 28 18" <br />BOOT AND CLAMPS <br />.40 <br />MINI HYDROSTATIC 212 <br />SENSOR IN BRINE <br />FACTORY SUPPLIED <br />RESERVOIR ° <br />PEA GRAVEL BACKFILL (TYP.) 6 Q <br />2 -IN -1 SENSOR BOX217 <br />JUNCTION BOX 188 <br />SEE STATIC GROUNDING DETAILS - <br />ON SHEET G.0.7.2 (TYP.) <br />#4 STRANDED BARE CU <br />GROUND WIRE TO OTHER <br />TANKS (TYP.) <br />#4 STRANDED BARE CU <br />GROUND WIRE TO <br />GROUND ROD (TYP.) <br />1>, FRP BONDED ENTRY FITTING <8>124 <br />(TYP.) <br />1" MONITORING CONDUIT (TYP.) 5 @87 <br />(ROBROY THROUGH SUMP ONLY) <br />42" DOUBLE WALL POLYGON SUMP <br />BODY (8) FLAT PANELS <br />5 GALLON SPILL CONTAINER. <br />NO DRAIN VALVE (TYP.) <br />18" MANHOLE 0 PLASTIC CAP <br />4" MIN. TO 4" VAPOR RECOVERY ADAPTER & CAP IN SPILL 0 SUPPLIED BY BP <br />TOP OF SPILL 39 40 CONTAINMENT FILL BOX. PER CARB EVR VR -10 , J -BOX (TYP.)189 1 2 3 4 <br />BUCKET NO DRAIN VALVE (TYP.) <br />3'-88„ <br />•.: `°. . <br />.a a (TAPE z_ m PEA GRAVEL u ' V V166 9 <br />a ° DEPTH 6" BACKFILL 7 <br />a . ° MIN. 12" vgi 4" FRP ANNULAR <br />MAX.) SEAL OFF 16 RISER <br />4 191 <br />G 6" WIDE DETECTABLE UNDERGROUND 18 6 <br />MARKING TAPE <br />EMPIRE MAGNATEC #32-1436 18 TO TURBINE <br />4" GALV. STEEL RISERS STAGE SUMP <br />22 1 VAPOR RISER IS IN SAME HOME RUN I <br />9 PLANE AS TANK LEVEL GAUGE I <br />IN THIS VIEW 171 6 <br />BRINE RESERVOIR TO FILL SUMP <br />HYDROSTATIC O <br />SENSOR <br />SUMP MONITOR LIQUID SENSOR 202 H I 12, <br />MOUNTED IN HOLDER M.5.3.15 I <br />I 19 EXTRACTOR FITTING <br />I I 4"x4"x3"x2" <br />I i <br />I <br />1/4" DRAIN/TEST BUSHING. <br />OVERFILL PROTECTION DROP I FACTORY INSTALLED TO <br />TUBE SET AT 95% (TYP.) 41 16 TEST CONTINUITY <br />D: SECTION VIEW - FILL SIDE SUMP (SINGLE FILL W/ MANWAY) <br />SCALE: 3/4" = 1'-0" <br />SUMP MONITOR LIQUID SENSOR , <br />MANWAY JACK SCREW (TYP.) MOUNTED IN HOLDER <br />1 8" <br />3" D.W. FRP BONDED ENTRY FITTING & 12612 <br />4"x3" CONCENTRIC REDUCER W/ TEST UTA! <br />PORT & VACUUM TUBING ROUTED TO u�! <br />VAC SENSOR] <br />2" INSIDE 3" DW F.G. VACUUM <br />MONITORED VENT LINE <br />11 14 148 I <br />i <br />I <br />2" BELL X MALE ADAPTER (TYP.) 14 I ° <br />0 <br />2"X18" FLEX CONNECTOR 15 174 0 <br />E:3 <br />H <br />3.15 8" ACCESS PORT <br />t04)83" OVER 2" FIBERGLASS <br />CROSSOVER CONTAINS VACUUM <br />TUBING ONLY TO VAC SENSOR <br />ASSEMBLY <br />2 3" FRP BONDED ENTRY FITTING & <br />4'x3' CONCENTRIC REDUCER W/ <br />TEST PORT & PLUG <br />14 148 3" OVER 2" FIBERGLASS CROSSOVER <br />CONTAINS VACUUM TUBING ONLY TO <br />VAC SENSOR ASSEMBLY <br />j o 3" D.W. FRP BONDED ENTRY FITTING <br />i 12 126 & 4x3 CONCENTRIC REDUCER W/ <br />i TEST PORT & PLUG <br />016 2" CAP. DRILL HOLES IN END AND <br />0 INSTALL GROMMETS FOR TUBING <br />PASS THROUGH <br />- - - „ <br />TANK ` <br />o <br />I <br />SLOPE CONCRETE AWAY FROM ALL MANHOLES 1 " RISE OVER 12" RUN10 <br />W <br />4 VAPOR RECOVERY ADAPTER & CAP IN SPILL <br />42" I.D. <br />0 <br />w <br />4 VAPOR RECOVERY ADAPTER & CAP IN SPILL <br />i <br />39 40 CONTAINMENT FILL BOX. PER CARB EVR VR -102, <br />4" FILL ADAPTER <br />AND CAP IN SPILL 37 38 <br />X39 40 CONTAINMENT FILL BOX. PER CARB EVR VR -102, <br />o <br />NO DRAIN VALVE TO BE INSTALLED ON VAPOR <br />CONTAINMENT FILL BOX <br />° 0 <br />i I <br />I I <br />RECOVERY SPILL BUCKET <br />3" BELL X <br />MALE ADAPTER (TYP.) 15 <br />I I I <br />I I I <br />ALL MANHOLE ACCESS COVERS TO BELOW GRADE <br />3„ BELL X <br />MALE ADAPTER (TYP.) 15 <br />� � I <br />SHALL BE LIQUID TIGHT AND LOCKABLE <br />CONNECTIONS, AND CONTINUES 3" TO OTHER TANKS. <br />0 0 <br />SHALL BE LIQUID TIGHT AND LOCKABLE <br />3" INSIDE 4" <br />D.W. F.G. VACUUM <br />o o® ®® vo®®v o <br />FIBRELITE. MULTI -PORT DUAL POINT FILL SPILL <br />MONITORED <br />VAPOR RECOVERY <br />O <br />SENSOR LOCATION AND HOMERUN TO BLDG. PROVIDE SEAL -OFFS IN <br />28 <br />CONTAINMENT ASSEMBLY W/ (2) 5 GALLON SPILL <br />13 11 14815 <br />BUCKETS CARB STAGE I EVR COMPLIANT PER <br />INTRINSICALLY SAFE TROUGH IN BUILDING. CONDUITS SHALL CONTAIN <br />13 1 1 148 15 <br />ONLY LOW VOLTAGE WIRING FOR SENSORS. ALL CONDUIT PENETRATIONS <br />[DIAMOND <br />VR -102, <br />MUST BE MADE WITH ROBROY PVC COATED CONDUIT ONLY. <br />15> CLEARANCE OR THE USE OF AN ANTI CHAFING DEVICE MUST BE INSTALLED. <br />z <br />DIAMOND PLATE <br />42" DIA. BRINE MONITORED DOUBLE WALL <br />4" D.W. FRP <br />BONDED ENTRY FITTING & <br />USE OF OVERFLOW PREVENTION DROP TUBE FLAPPER VALVE SET AT <br />o <br />CONTAINMENT SUMP (TYP.) <br />5"x4" CONCENTRIC <br />128 129 <br />REDUCER W/ TEST PORT <br />LD,,_ ..0 <br />O7 <br />& 1/4" PLUG VACUUM SENSOR ASSEMBLY <br />176 15 3"X18" FLEX <br />CONNECTOR <br />LOCATED AT 20K OR 30K TANK. <br />QB.PLAN VIEW - FILL SIDE SUMP (SINGLE FILL W/O MANWAY) <br />SCALE: 3/4" = 1'-0" <br />FIBRELITE. MULTI -PORT DUAL POINT FILL 28 <br />SPILL CONTAINMENT ASSEMBLY W/ (2) 5 <br />GALLON SPILL BUCKETS CARB STAGE I EVR10 <br />COMPLIANT PER VR -102, <br />4" FILL ADAPTER AND CAP IN SPILL 37 38 <br />CONTAINMENT FILL BOX (TYP.) <br />WATERTIGHT SUMP SHIELD 28 18" <br />BOOT AND CLAMPS <br />.40 <br />MINI HYDROSTATIC 212 <br />SENSOR IN BRINE <br />FACTORY SUPPLIED <br />RESERVOIR ° <br />PEA GRAVEL BACKFILL (TYP.) 6 Q <br />2 -IN -1 SENSOR BOX217 <br />JUNCTION BOX 188 <br />SEE STATIC GROUNDING DETAILS - <br />ON SHEET G.0.7.2 (TYP.) <br />#4 STRANDED BARE CU <br />GROUND WIRE TO OTHER <br />TANKS (TYP.) <br />#4 STRANDED BARE CU <br />GROUND WIRE TO <br />GROUND ROD (TYP.) <br />1>, FRP BONDED ENTRY FITTING <8>124 <br />(TYP.) <br />1" MONITORING CONDUIT (TYP.) 5 @87 <br />(ROBROY THROUGH SUMP ONLY) <br />42" DOUBLE WALL POLYGON SUMP <br />BODY (8) FLAT PANELS <br />5 GALLON SPILL CONTAINER. <br />NO DRAIN VALVE (TYP.) <br />18" MANHOLE 0 PLASTIC CAP <br />4" MIN. TO 4" VAPOR RECOVERY ADAPTER & CAP IN SPILL 0 SUPPLIED BY BP <br />TOP OF SPILL 39 40 CONTAINMENT FILL BOX. PER CARB EVR VR -10 , J -BOX (TYP.)189 1 2 3 4 <br />BUCKET NO DRAIN VALVE (TYP.) <br />3'-88„ <br />•.: `°. . <br />.a a (TAPE z_ m PEA GRAVEL u ' V V166 9 <br />a ° DEPTH 6" BACKFILL 7 <br />a . ° MIN. 12" vgi 4" FRP ANNULAR <br />MAX.) SEAL OFF 16 RISER <br />4 191 <br />G 6" WIDE DETECTABLE UNDERGROUND 18 6 <br />MARKING TAPE <br />EMPIRE MAGNATEC #32-1436 18 TO TURBINE <br />4" GALV. STEEL RISERS STAGE SUMP <br />22 1 VAPOR RISER IS IN SAME HOME RUN I <br />9 PLANE AS TANK LEVEL GAUGE I <br />IN THIS VIEW 171 6 <br />BRINE RESERVOIR TO FILL SUMP <br />HYDROSTATIC O <br />SENSOR <br />SUMP MONITOR LIQUID SENSOR 202 H I 12, <br />MOUNTED IN HOLDER M.5.3.15 I <br />I 19 EXTRACTOR FITTING <br />I I 4"x4"x3"x2" <br />I i <br />I <br />1/4" DRAIN/TEST BUSHING. <br />OVERFILL PROTECTION DROP I FACTORY INSTALLED TO <br />TUBE SET AT 95% (TYP.) 41 16 TEST CONTINUITY <br />D: SECTION VIEW - FILL SIDE SUMP (SINGLE FILL W/ MANWAY) <br />SCALE: 3/4" = 1'-0" <br />SUMP MONITOR LIQUID SENSOR , <br />MANWAY JACK SCREW (TYP.) MOUNTED IN HOLDER <br />1 8" <br />3" D.W. FRP BONDED ENTRY FITTING & 12612 <br />4"x3" CONCENTRIC REDUCER W/ TEST UTA! <br />PORT & VACUUM TUBING ROUTED TO u�! <br />VAC SENSOR] <br />2" INSIDE 3" DW F.G. VACUUM <br />MONITORED VENT LINE <br />11 14 148 I <br />i <br />I <br />2" BELL X MALE ADAPTER (TYP.) 14 I ° <br />0 <br />2"X18" FLEX CONNECTOR 15 174 0 <br />E:3 <br />H <br />3.15 8" ACCESS PORT <br />t04)83" OVER 2" FIBERGLASS <br />CROSSOVER CONTAINS VACUUM <br />TUBING ONLY TO VAC SENSOR <br />ASSEMBLY <br />2 3" FRP BONDED ENTRY FITTING & <br />4'x3' CONCENTRIC REDUCER W/ <br />TEST PORT & PLUG <br />14 148 3" OVER 2" FIBERGLASS CROSSOVER <br />CONTAINS VACUUM TUBING ONLY TO <br />VAC SENSOR ASSEMBLY <br />j o 3" D.W. FRP BONDED ENTRY FITTING <br />i 12 126 & 4x3 CONCENTRIC REDUCER W/ <br />i TEST PORT & PLUG <br />016 2" CAP. DRILL HOLES IN END AND <br />0 INSTALL GROMMETS FOR TUBING <br />PASS THROUGH <br />- - - „ <br />LOCATED AT 20K OR 30K TANK. <br />E: PLAN VIEW - FILL SIDE SUMP (SINGLE FILL W/ MANWAY) <br />SCALE: 3/4" = 1'-0" <br />SLIP ON RISER <br />FIELD SEALED JOINT. — <br />(ADHESIVE SUPPLIED <br />W/ KIT) <br />FACTORY`�� <br />LAY-UP DW COLLAR <br />BONDED TO <br />TANK <br />i <br />JOINT DETAILS <br />37" O.D. (SINGLE FILL) <br />III <br />TANK ` <br />o <br />I <br />SLOPE CONCRETE AWAY FROM ALL MANHOLES 1 " RISE OVER 12" RUN10 <br />W <br />z <br />42" I.D. <br />0 <br />w <br />4 VAPOR RECOVERY ADAPTER & CAP IN SPILL <br />FIBER REINFORCEMENT TO BE USED. PRE -MIX UNIFORMLY THROUGHOUT <br />Z <br />J <br />i ° <br />X39 40 CONTAINMENT FILL BOX. PER CARB EVR VR -102, <br />4" FILL ADAPTER <br />AND CAP IN SPILL 37 38 <br />Q <br />° 0 <br />NO DRAIN VALVE TO BE INSTALLED ON VAPOR <br />CONTAINMENT FILL BOX <br />Q <br />i <br />i <br />10 <br />RECOVERY SPILL BUCKET <br />3„ BELL X <br />MALE ADAPTER (TYP.) 15 <br />° 0 0 01 <br />I I <br />ALL MANHOLE ACCESS COVERS TO BELOW GRADE <br />CONNECTIONS, AND CONTINUES 3" TO OTHER TANKS. <br />I <br />I I <br />SHALL BE LIQUID TIGHT AND LOCKABLE <br />3” INSIDE 4" <br />D.W. F.G. VACUUM <br />o o® ®® vo®®v o <br />FIBRELITE. MULTI -PORT DUAL POINT FILL SPILL <br />MONITORED <br />VAPOR RECOVERY <br />O <br />SENSOR LOCATION AND HOMERUN TO BLDG. PROVIDE SEAL -OFFS IN <br />28 CONTAINMENT ASSEMBLY W/ (2) 5 GALLON SPILL <br />BUILDING & PRIOR TO LEAVING HAZARDOUS AREA. ROUTE TO <br />BUCKETS CARB STAGE I EVR COMPLIANT PER <br />INTRINSICALLY SAFE TROUGH IN BUILDING. CONDUITS SHALL CONTAIN <br />13 1 1 148 15 <br />ONLY LOW VOLTAGE WIRING FOR SENSORS. ALL CONDUIT PENETRATIONS <br />[DIAMOND <br />VR -102, <br />MUST BE MADE WITH ROBROY PVC COATED CONDUIT ONLY. <br />15> CLEARANCE OR THE USE OF AN ANTI CHAFING DEVICE MUST BE INSTALLED. <br />z <br />PLATE <br />42 DIA. BRINE MONITORED DOUBLE WALL <br />4" D.W. FRP <br />BONDED ENTRY FITTING & <br />USE OF OVERFLOW PREVENTION DROP TUBE FLAPPER VALVE SET AT <br />o <br />CONTAINMENT SUMP (TYP.) <br />5"x4" CONCENTRIC <br />128 129 <br />REDUCER W/ TEST PORT <br />LD,,_ ..0 <br />O7 <br />& 1/4" PLUG VACUUM SENSOR ASSEMBLY <br />176 15 3"X18" FLEX <br />CONNECTOR <br />LOCATED AT 20K OR 30K TANK. <br />E: PLAN VIEW - FILL SIDE SUMP (SINGLE FILL W/ MANWAY) <br />SCALE: 3/4" = 1'-0" <br />SLIP ON RISER <br />FIELD SEALED JOINT. — <br />(ADHESIVE SUPPLIED <br />W/ KIT) <br />FACTORY`�� <br />LAY-UP DW COLLAR <br />BONDED TO <br />TANK <br />i <br />JOINT DETAILS <br />37" O.D. (SINGLE FILL) <br />III <br />u <br />o <br />I <br />SLOPE CONCRETE AWAY FROM ALL MANHOLES 1 " RISE OVER 12" RUN10 <br />W <br />z <br />42" I.D. <br />0 <br />w <br />z o <br />FIBER REINFORCEMENT TO BE USED. PRE -MIX UNIFORMLY THROUGHOUT <br />Z <br />J <br />CONCRETE. <br />VAPOR RECOVERY PIPING. <br />Lit <br />N <br />DW POLYGON BODY <br />Q <br />g <br />7 <br />Q <br />OCONTRACTOR TO ADDITIONALLY GLASS WRAP & LAMINATE AT CONNECTION FOLLOWING CURING OF <br />ADHESIVE. SPECIFIC ATTENTION MUST BE GIVEN TO SURFACE PREP AS TESTING REQUIREMENTS <br />WILL DETECT THE SMALLEST OF FLAWS. ALL MATERIALS MUST BE COMPATIBLE WITH GASOLINE, <br />GASOLINE WITH 15% MTBE (METHYL TERTIARY -BUTYL ETHER), OR GASOLINE WITH 10% ETCH <br />(ETHANOL). FIBERGLASS AND RESIN MUST EXTEND 1/2" BEYOND COVERAGE OF ADHESIVE. <br />OTHE STRAP CHANNEL IF PRESENT ON THE FILL SIDE SUMP DOES NOT "COMMUNICATE" WITH <br />THE INSIDE OF THE SUMP. CONTRACTOR TO BE SURE TO LEAVE UNOBSTRUCTED PATH FOR <br />STRAP TO PENETRATE INTO THE CHANNEL SO THAT TANKS MAY BE PROPERLY ANCHORED. <br />F: DOUBLE WALL FILL SUMP RISER <br />SCALE: 3/4" = 1'-0" <br />U2 <br />42" DIA. POLYGON SUMP BODY <br />(8) 17 3/8" FLAT PANELS <br />1/4" DRAIN/TEST BUSHING. <br />FACTORY INSTALLED <br />NOTE: <br />CONTRACTOR SHALL BE HELD RESPONSIBLE <br />FOR PROPER INSTALLATION & PREPARATION <br />PER MANUFACTURERS INSTRUCTIONS AND <br />SHALL REINSTALL SUMPS IF HYDROSTATIC <br />TESTING SHOWS LEAKING IN THIS AREA OF <br />THE SUMP. <br />DOUBLE WALL SUMP <br />2" FIBERGLASS 14 WALL <br />NIPPLE D.W. RIGID SUMP <br />2" FIBERGLASS 16 PENETRATION FITTING <br />END CAP 12 126 <br />1/4" VACUUMIF <br />TUBING 2" INSIDE 3" DOUBLE <br />DRILL AND TAP CAP WALL FIBERGLASS <br />1 /2" WATER -TIGHT FOR 1/2" CORD GRIP. CROSSOVER PIPE FOR <br />ELECTRICAL CORD (APPLY PIPE SEALANT VACUUM TUBING <br />GRIPS (RATED FOR AS NEEDED) 14 148 <br />FUEL COMPATIBILITY) <br />G: ELEVATION - INTERSTITIAL SPACE MONITOR H: VACUUM TUBE AT SUMP ENTRY DETAIL <br />SCALE: 3/4" = 1'-0" <br />SCALE: 3/4" = 1'-0" <br />®NOTES <br />u <br />O1 <br />SLOPE CONCRETE AWAY FROM ALL MANHOLES 1 " RISE OVER 12" RUN10 <br />INSTALL TANK ID MARKERS IN THE SPILL CONTAINMENT MANHOLES. COVERS <br />- BLUE <br />LOW SLOB <br />SHALL BE PRIMED AND PAINTED ACCORDING TO SPECIFICATIONS. <br />O2 <br />FIBER REINFORCEMENT TO BE USED. PRE -MIX UNIFORMLY THROUGHOUT <br />11 SECONDARY CONTAINMENT IS REQUIRED FOR ALL VENT AND STAGE II <br />DIESEL <br />CONCRETE. <br />VAPOR RECOVERY PIPING. <br />OREINFORCING <br />BARS TO BE NO LESS THAN 2" AND NO MORE THAN <br /><@>NOT USED <br />4" FROM SURFACE. <br />CONCRETE SLAB AROUND MANHOLE WITH 4-#3 REBAR 60" IN <br />13 LAYOUT TANKS & STAGE II VAPOR RECOVERY PIPING SUCH THAT THE STAGE <br />OREINFORCE <br />4 <br />LENGTH. PLACE REBAR 6" FROM SIDES OF BOX. <br />II PIPING DRAINS & ENTERS INTO REGULAR UNLEADED TANK FIRST W/ 3" <br />0 <br />CONNECTIONS, AND CONTINUES 3" TO OTHER TANKS. <br />ONE 1" STANDARD MONITORING HOMERUN CONDUIT TO EACH TANK. <br />FOR STANDARD MONITORING DEVICES, LOOP CONTAINMENT SUMP <br />CONCRETE SHALL BE THICKENED AT THE THE FILL SUMPS DOWN TO <br />SENSORS, PLLD, VAC SENSORS & TANK GAUGE TO TANK INTERSTITIAL <br />14 BELOW THE TOP OF CONTAINMENT OF THE DOUBLE WALL SUMP AS <br />O <br />SENSOR LOCATION AND HOMERUN TO BLDG. PROVIDE SEAL -OFFS IN <br />REQUIRED. DIMENSION OF SLAB THICKNESS VARIES WITH SITE CONDITIONS. <br />BUILDING & PRIOR TO LEAVING HAZARDOUS AREA. ROUTE TO <br />SEAL: <br />INTRINSICALLY SAFE TROUGH IN BUILDING. CONDUITS SHALL CONTAIN <br />0 <br />ONLY LOW VOLTAGE WIRING FOR SENSORS. ALL CONDUIT PENETRATIONS <br />CROSSING FLEX CONNECTORS MUST MAINTAIN A MINIMUM OF 2 INCH <br />ATF <br />MUST BE MADE WITH ROBROY PVC COATED CONDUIT ONLY. <br />15> CLEARANCE OR THE USE OF AN ANTI CHAFING DEVICE MUST BE INSTALLED. <br />z <br />GRAVEL BACKFILL. ALL SUBSTITUTES MUST BE APPROVED BY <br />OVERFLOW PROTECTION: UST OVERFLOW COMPLIANCE IS ACHIEVED BY <br />OPEA <br />6 <br />MANUFACTURER AND OWNER'S FIELD REPRESENTATIVE. <br />USE OF OVERFLOW PREVENTION DROP TUBE FLAPPER VALVE SET AT <br />o <br />Z <br />95% AND IS IN ACCORDANCE WITH FEDERAL AND STATE GUIDELINES <br />LD,,_ ..0 <br />O7 <br />PIPING SHALL BE LAID AND CONTINUOUSLY SUPPORTED ON A 6"16 <br />COMPACTED PEA GRAVEL BEDDING. PIPING SHALL NOT BE <br />FOR UST OVERFILL REQUIREMENTS. <br />SUPPORTED BY BLOCKS, PLANKS, OR OTHER DEBRIS. <br />AN OVERFILL ALARM AND ACKNOWLEDGE SWITCH TIED INTO THE VEEDER <br />ROOT AUTOMATIC TANK GAUGE SYSTEM. THE MONITORING SYSTEM <br />z U U o <br />z z <br />Q <br />OALL <br />ENTRIES TO BE PERPENDICULAR TO CONTAINMENT SUMP. OFFLINE <br />PROVIDES AN AUDIBLE AND VISUAL ALARM WHEN THE TANK(S) ARE <br />06 <br />INSTALLATION NOT PERMITTED. <br />FILLED TO THE 90% LEVEL. <br />O9 <br />REAM ALL RISERS FOR FULL PIPE BORE IF REQUIRED. <br />(D <br />z = <br />2 0- <br />z <br />NOTE: CONTRACTOR TO USE ADDITIONAL <br />g <br />GALVANIZED FITTINGS AS REQUIRED TO <br />DEVELOPMENT INFORMATION: <br />MINIMIZE BENDS IN FLEXIBLE CONNECTORS <br />ADDRESS <br />2510 S. STATE HWY 99 W. FRONTAGE ROAD <br />XX NOTE: INDICATES ITEMS FOUND ON MATERIALS LIST SHEETS M.5.3.01 <br />DESIGNED BY: <br />& M.5.3.02 <br />PRODUCT SYMBOLOGY <br />OPTION: <br />PAINT API PRODUCT <br />CODE COLOR ON LID <br />SLAB ACCESS BOX �� _ <br />SHOWN WITHOUT LID - �� ID COLLAR <br />i <br />API COLOR -SYMBOL SYSTEM FOR PRODUCT IDENTIFICATION <br />WHITE CROSS <br />ON RED <br />CIRCLE <br />WHITE CROSS <br />ON BLUE <br />CIRCLE <br />BLACK CROSS <br />ON WHITE <br />CIRCLE <br />YELLOW <br />HEXAGON <br />BLACK <br />LETTERS ON <br />BRONZE <br />BACKGROUND <br />BLACK <br />TRIANGLE ON <br />WHITE FIELD <br />UNLEADED ETHANOL <br />MON GRAIM <br />N�o <br />0 MIDDLE GRADE ! ��- <br />i <br />LOW GRADE <br />OBSERMLTION WELL YLPOR RECOVERY WASTE OIL <br />REF: API 1637 - PRODUCT SYMBOLS <br />NOTE: THE ABOVE SYMBOLS REPRESENT INDUSTRY GUIDELINES <br />FOR PRODUCT IDENTIFICATION. CONSULT LOCAL DISTRIBUTION <br />MANAGER FOR LOCAL METHOD OF PRODUCT IDENTIFICATION TO <br />BE USED. <br />STANDARD API COLOR AND <br />WHITE CROSS ON <br />RED CIRCLE, WITH <br />WHITE RING <br />WHITE CROSS ON <br />BLUE CIRCLE, WITH <br />WHITE RING <br />BLACK CROSS ON <br />WHITE CIRCLE, WITH <br />WHITE RING <br />YELLOW <br />HEXAGON/BLACK <br />LETTER (U) <br />BLUE STRIPE ON <br />YELLOW HEXAGON <br />ORANGE CIRCLE <br />PURPLE SQUARE <br />IDENTIFICATION SYMBOLS SCALE: NONE <br />STAGE I VAPOR ornnii Ov <br />FILL POR' <br />THIS AREA TO REMAIN <br />GREY OR WHITE <br />8" ACCESS PORT TO BE <br />ORIENTATED TO THE SAME <br />SIDE AS TANK LEVEL <br />GAUGE <br />API STANDARD COLORS <br />UNLEADED PREMIUM <br />u <br />REGULAR UNLEADED <br />- WHITE <br />UNLEADED PLUS <br />- BLUE <br />LOW SLOB <br />ULTRA LOW SULFUR <br />016H SULFUR <br />DIESEL <br />DIESEL <br />DIESEL <br />E85 <br />FLEX FUEL <br />OBSERMLTION WELL YLPOR RECOVERY WASTE OIL <br />REF: API 1637 - PRODUCT SYMBOLS <br />NOTE: THE ABOVE SYMBOLS REPRESENT INDUSTRY GUIDELINES <br />FOR PRODUCT IDENTIFICATION. CONSULT LOCAL DISTRIBUTION <br />MANAGER FOR LOCAL METHOD OF PRODUCT IDENTIFICATION TO <br />BE USED. <br />STANDARD API COLOR AND <br />WHITE CROSS ON <br />RED CIRCLE, WITH <br />WHITE RING <br />WHITE CROSS ON <br />BLUE CIRCLE, WITH <br />WHITE RING <br />BLACK CROSS ON <br />WHITE CIRCLE, WITH <br />WHITE RING <br />YELLOW <br />HEXAGON/BLACK <br />LETTER (U) <br />BLUE STRIPE ON <br />YELLOW HEXAGON <br />ORANGE CIRCLE <br />PURPLE SQUARE <br />IDENTIFICATION SYMBOLS SCALE: NONE <br />STAGE I VAPOR ornnii Ov <br />FILL POR' <br />THIS AREA TO REMAIN <br />GREY OR WHITE <br />8" ACCESS PORT TO BE <br />ORIENTATED TO THE SAME <br />SIDE AS TANK LEVEL <br />GAUGE <br />API STANDARD COLORS <br />UNLEADED PREMIUM <br />- RED <br />REGULAR UNLEADED <br />- WHITE <br />UNLEADED PLUS <br />- BLUE <br />ULTRA LOW SULFUR DIESEL <br />- YELLOW <br />ACCESS COVER IDENTIFICATION <br />STANDARD TWO POINT FILL SCALE: NONE <br />CLIENT: <br />bp <br />IFF <br />ARCO <br />BP WEST COAST PRODUCTS, LLC <br />NO. <br />DATE <br />DESCRIPTION <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />io <br />0 <br />SEAL: <br />FESS /0 <br />Gf-�gp�l <br />0 <br />NO. 36475 <br />* XP. 6-30-22 <br />ATF <br />U'r CAUF��� <br />z <br />LU <br />LU <br />•Q <br />co <br />rn <br />bz <br />o <br />Z <br />z~�— <br />LD,,_ ..0 <br />mZ <br />0 <br />IodM .. <br />_ Q U <br />cc <br />Qw <br />I I w w <br />cn Z LL <br />z O z o <br />z U U o <br />z z <br />Q <br />p Z N <br />wz0-- <br />�w <br />LUQ}Z� <br />z Q -- <br />06 <br />.t <br />Z � <br />Q <br />W CO LU <br />0 <br />(D <br />z = <br />2 0- <br />z <br />g <br />a_ <br />DEVELOPMENT INFORMATION: <br />SITE ADDRESS: <br />ADDRESS <br />2510 S. STATE HWY 99 W. FRONTAGE ROAD <br />SAN JOAQUIN COUNTY, CA 95205 <br />DESIGNED BY: <br />CHECKED BY: <br />DRAWN BY: <br />ER <br />DATE: <br />PROJECT NO: <br />10/28/2019 <br />DRAWING TITLE: <br />GASOLINE FILL SIDE SUMP <br />INSTALLATION DETAILS <br />(OPW VR -102 W/ MANWAY) <br />(DOUBLE WALL VENTNAPOR) <br />SHEET NO: <br />Ms5,3,17 <br />