REVISIONS
<br /> TENTATIVE IMPROVEMENT PLANS FOR: NO. DATE: DESCRIPTION
<br /> 115/13/21 LFD- 1 ST REVIEW
<br /> SMA CAK S BAK RY STOR 05/18/21 LBID- 1ST REVIEW
<br /> 15040 S. HARLAN ROAD, CITY OF LATHROP, STATE OF CALIFORNIA, 95330 1F
<br /> WITHIN PARCEL=APN: 196- 11-020 54 ,
<br /> 59'-0" O �#
<br /> A05/13/21 LFD- 1 ST REVIEW FAIFC 906.1 THRU 906.9.3.
<br /> TENTATIVE IMPROVEMENTS 2019 CALIFORNIA EXISTING BUILDING o
<br /> ° CODE
<br /> PROPOSED TENANTS "SMALLCAKES" BAKERY STORE,
<br /> OF THIS EXISTING VACANT COMMERCIAL SPACE,WILL HAVE A CUSTOMER50
<br /> PROPOSED KITCHEN D CHAPTER 1: SCOPE AND ADMINISTRATION
<br /> SERVING COUNTER,A BAKERY STATION,AN ENCLOSED KITCHEN CLEANING CEILING HEIGHT= 10'-0" I �r
<br /> DIVISION I-CALIFORNIA ADMINISTRATION
<br /> AREA AND A UNISEX ALL-GENDER BATHROOM. THE PREVIOUS BUILT SPACE EXISTING (77 ft) PROPOSED BAKERY FLO " �v {
<br /> HAS NO IMPROVEMENTS FROM THE PREVIOUS OCCUPANTS (APNA PUNJAB). _ CEILING HEIGHT= 10'-0" .
<br /> RESTROOM(52.5 ft2) (1,502 ft2)
<br /> CEILING HEIGHT= 10-0 APPLICATIONS.1.1.3.1 NON STATE-REGULATED BUILDINGS, STRUCTURES AND
<br /> m
<br /> CLIENT WILL PROVIDE SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH `� D EXCEPT AS MODIFIED BY LOCAL ORDINANCE PURSUANT TO SECTION 1.1.8, r 1 y Y
<br /> E OSR gMI LI,A P 1ST REVIEW TPPROVAL LETTER. QIFC 906.1 THRU 906.9.3. THE FOLLOWING STANDARDS IN THE CALIFORNIA CODE OF REGULATIONS,
<br /> THIS SITE HAS A FRONTAGE ROAD(HARLAN RD)ON THE NORTH SIDE OF THE D TITLE 24,PARTS 2,2.5, 3,4, 5, 6,9, 10 AND 11 SHALL APPLY TO ALL .
<br /> OCCUPANCIES AND APPLICATIONS NOT REGULATED BY A STATE AGENCY. *,
<br /> PROPERTY.
<br /> THE CITY OF LATHROP STORM ACCESS IS NORTH OF THE PROPERTY,WEST OF DIVISION II
<br /> THE INTERSTATE 5 ON-RAMP. D SCOPE AND ADMINISTRATION
<br /> THE CITY OF LATHROP SEWER ACCESS ON HARLAN RD. EXISTING
<br /> ELECToo .., a o
<br /> (DOOR LOCK w SECTION 106-CONSTRUCTION DOCUMENTS ? ;; • g 0
<br /> THE CAL WATER IS AT HARLAN RD. (DOOR LOCKED) v
<br /> W 106.1 GENERAL. Q °c V ? A
<br /> THE PG&E GAS UTILITY IS AT HARLAN RD. U N SUBMITTAL DOCUMENTS CONSISTING OF CONSTRUCTION DOCUMENTS
<br /> QA O N SPECIAL INSPECTION AND STRUCTURAL OBSERVATION PROGRAMS, ��
<br /> 1 IF 906.1 THRU 906.9. w
<br /> YOU MUST CALL CITY OF LATHROP,CAL WATER,AND PG&E FOR U A D INVESTIGATION AND EVALUATION REPORTS,AND OTHER DATA SHALL BE t ^ ❑ x F� zi
<br /> PROPOSED TIE-INS/STUB-UPS TO THESE BUILT UTILITIES. O A ° SUBMITTED IN TWO OR MORE SETS WITH EACH APPLICATION FOR A PERMIT.
<br /> UTILITY NOTES: EXCEPTION: THE CODE OFFICIAL IS AUTHORIZED TO WAIVE THE
<br /> O SUBMISSION OF CONSTRUCTION DOCUMENTS AND OTHER DATA NOT
<br /> THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY -" a 7� b REQUIRED TO BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL Z 'r
<br /> INFORMATION AND EXISTING DRAWINGS.THE SURVEYOR MAKES NO GUARANTEE W D IF IT IS FOUND THAT THE NATURE OF THE WORK APPLIED FOR IS SUCH
<br /> THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE ``' ° THAT REVIEWING OF CONSTRUCTION DOCUMENTS IS NOT NECESSARY Z
<br /> AREA,EITHER IN SERVICE OR ABANDONED.THE SURVEYOR FURTHER DOES NOT TO OBTAIN COMPLIANCE WITH THIS CODE.
<br /> GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT PROPOSED OFFICE ° D
<br /> LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS PROPOSED STORAGE ROOM CEILING HEIGHT= 10'-0"
<br /> ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE.THE SURVEYOR HAS a CEILING HEIGHT= 10'-0" (144 ft2) 106.2 CONSTRUCTION DOCUMENTS. O a
<br /> NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. Q (100 ft2) D CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE WITH SECTIONS Uh
<br /> A 106.2.1 THROUGH 106.2.5. o
<br /> BUILDING CODE ANALYSIS:
<br /> EXISTING 4"x4"
<br /> D 106.2.1 CONSTRUCTION DOCUMENTS. �
<br /> Q 05/18/21 LBID C1
<br /> COO
<br /> w STEEL POLE CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON o c
<br /> OCCUPANCY GROUP: GROUP B-1 (CBC 304.1) 2ND COMMENT O FROM FLOORL* bn
<br /> SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE PERMITTED TO
<br /> TYPE OF CONSTRUCTION: SB EXISTING) Q 05/18/21 LBID 3RD COMMEN p' "HRU CEILING
<br /> FIRE SPRINKLERS: YES BE SUBMITTED WHERE APPROVED BY THE CODE OFFICIAL. CONSTRUCTION °' v b
<br /> DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE THE � E N �
<br /> STORIES: 1 1&FC 906.1 THR=906.9.3. LOCATION,NATURE AND EXTENT OF THE WORK PROPOSED AND SHOW �: [ ,o
<br /> BUILDING HEIGHT:
<br /> 101-011N IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS CODE 3
<br /> ALLOWABLE FLOOR AREA: 1,920ft2 p ❑ .� a
<br /> FLOOR AREA: 1,920ft2 ° AND RELEVANT LAWS,ORDINANCES,RULES AND REGULATIONS,AS
<br /> PROPOSED HALLWAY DETERMINED BY THE CODE OFFICIAL. THE WORK AREAS SHALL BE
<br /> A05/18/21 LBID 4TH COMMENT 5ft WIDE SHOWN.
<br /> OCCUPANCY LOAD PER(CBC 1004-TABLE 1004.5) PERSONS 106.2.3 MEANS OF EGRESS.
<br /> ACCESSORY STORAGE AREAS 1 THE CONSTRUCTION DOCUMENTS FOR ALTERATIONS—LEVEL 2, V1 O Q
<br /> ASSEMBLY WITHOUT FIXED SEATS (STANDING SPACES) 42 T BUILDING SPACE ALTERATIONS—LEVEL 3,ADDITIONS AND CHANGES OF OCCUPANCY SHALL Q'
<br /> BUSINESS AREAS 6 SHOW IN SUFFICIENT DETAIL THE LOCATION, CONSTRUCTION, SIZE AND Q O Q
<br /> KITCHEN,COMMERCIAL 3 CHARACTER OF ALL PORTIONS OF THE MEANS OF EGRESS IN COMPLIANCE
<br /> TOTAL OCCUPANCY LOAD 52 PROPOSED LIFE SAVING PLAN WITH THE PROVISIONS OF THIS CODE. THE CONSTRUCTION DOCUMENTS Q ���//�� aJ Z
<br /> SHALL DESIGNATE THE NUMBER OF OCCUPANTS TO BE ACCOMMODATED IN V1 Q N
<br /> 05/18/21 LBID 4TH COMMENT LEGEND INC
<br /> SCALE: 1/4"= 1'-0" EVERY WORK AREA OF EVERY FLOOR AND IN ALL AFFECTED ROOMS a o
<br /> 19 CALIFORNIA BUILDING CODE AND SPACES. W
<br /> ILLUMINATED 1Q 05/13/21 LFD- 1ST REVIEW
<br /> CHAPTER 10-MEANS OF EGRESS EXIT SIGN Q U O
<br /> SECTION 1004-OCCUPANT LOAD 2018 INTERNATIONAL FIRE CODE04
<br /> o o
<br /> 1004.1 DESIGN OCCUPANT LOAD. IN DETERMINING MEANS OF EGRESS a STROBE W o
<br /> REQUIREMENTS, THE NUMBER OF OCCUPANTS FOR WHOM MEANS OF EGRESS CHAPTER 9-FIRE PROTECTION AND LIFE SAFETY SYSTEMS x
<br /> FACILITIES ARE PROVIDED SHALL BE DETERMINED IN ACCORDANCE WITH FIRST AIDKIT SECTION 906-PORTABLE FIRE EXTINGUISHERS M
<br /> THIS SECTION AND TABLE AN AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED IN EXISTING ISI
<br /> (MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT). BUILDINGS AND STRUCTURES WHEN REQUIRED IN CHAPTER 11.
<br /> FIRE EXTINGUISHER
<br /> 906.9-EXTINGUISHER INSTALLATION
<br /> THE INSTALLATION OF PORTABLE FIRE EXTINGUISHERS SHALL BE IN
<br /> ACCESSIBLE MEANS OF EGRESS ACCORDANCE WITH SECTIONS 906.9.1 THROUGH 906.9.3.
<br /> 906.9.1 -EXTINGUISHERS WEIGHING 40 POUNDS OR LESS
<br /> NOTE: ALL EXITS TO REMAIN UNOBSTRUCTED PORTABLE FIRE EXTINGUISHERS HAVING A GROSS WEIGHT NOT EXCEEDING Q
<br /> AND UNLOCKED AT ALL TIMES AND OPEN 40 POUNDS(18KG) SHALL BE INSTALLED SO THAT THEIR TOPS ARE NO MORE
<br /> WITHOUT OPERATION OR INTERIOR KEYED LOCKS THAN 5 FEET(1524MM)ABOVE THE FLOOR. �•G�
<br /> Q Aawp � �
<br /> 906.9.2 EXTINGUISHERS WEIGHING MORE THAN 40 POUNDS
<br /> HAND HELD PORTABLE FIRE EXTINGUISHERS HAVING A GROSS WEIGHT Q hal �I Q
<br /> EXCEEDING 4 POUNDS (18KG) SHALL BE INSTALLED SO THAT THEIR TOPS
<br /> ARE NOT MORE THAN 3.5 FEET(I067MM)ABOVE THE FLOOR. O
<br /> 906.9.3 -FLOOR CLEARANCE
<br /> THE CLEARANCE BETWEEN THE FLOOR AND THE BOTTOM OF INSTALLED [�
<br /> HAND HELD PORTABLE FIRE EXTINGUISHERS, SHALL BE NO LESS THAN 4 `— O
<br /> H
<br /> INCHES (102MM). W T^ FSI O O
<br /> NOTE: V1 CA
<br /> FIRE EXTINGUISHERS MUST BE MOUNTED AND HAVE PROPER SIGNAGE � ^ � �
<br /> POSTED PRIOR TO FINAL INSPECTION. � � � �
<br /> O Q,
<br /> UNAUTHORIZED CHANGES&USES:
<br /> The design firm preparing these plans will not be responsible for,or liable for,
<br /> unauthorized changes to or uses of these plans.All changes to these plans MUST be in
<br /> PERMIT NOTE: writing and must be approved by the preparer of these plans.
<br /> The issuance of a permit or approval of plans or specifications shall not be deemed or CHECKED BY: J.AGUIRRE (E.O.R.)
<br /> construed to be a permit for an approval of any violation of any of the provisions of the G.MENDOZA
<br /> California state building codes or local ordinances. CONSTRUCTION CONTRACTOR NOTE: DESIGNED BY: PHANTOM DESIGNS
<br /> Construction contractor agrees that in accordance with generally acepted construction G.MENDOZA
<br /> practices,construction contractor will be required to assume sole and complete DRAWN BY: PHANTOM DESIGNS
<br /> Responsibility for job site conditions during the course of constructionof the project, SCALE: SCALE: 1/4"= F-0"
<br /> DESIGN NOTE: including safety of all persons and property;that this requirement shall be made to apply
<br /> Electronic versions of the line work on this plan may not be consistent with other continuously and not to be limited to normal working hours, and construction contractor DATE: 04/30/2021
<br /> dimensions,notes,details,or descriptions which control the intent design. electronic 41 0 21 41 further agrees to defend,imdemnify and hold design professional harmless from any
<br /> versions of the plan are not to be used to establish the location of property or and all liability,real or alleged,in connection with the performance of work on this
<br /> improvements in the field. project, except liability arising from the sole negligence of the design professional.
<br /> SCALE: 1/4"= 1'-0" L 10
<br />
|